Effect of oral appliances on blood pressure in obstructive sleep apnea: A systematic review and meta-analysis

74Citations
Citations of this article
146Readers
Mendeley users who have this article in their library.

Abstract

Background: Obstructive sleep apnea (OSA) is an independent risk factor for the development of hypertension. However the effect of continuous positive airway pressure (CPAP) on lowering systemic blood pressure (BP) in OSA patients has been conflicting. Oral appliance (OA) therapy is an important alternative therapy to CPAP for patients with mild to moderate OSA. Objective: To conduct a meta-analysis of studies which have evaluated the effect of OAs on BP in patients with OSA. Data Sources: Studies were retrieved by searching PubMed (all studies that were published until December 15, 2011) Study Selection: Three independent reviewers screened citations to identify trials of the effect of OA on BP. Data Extraction: Data from observational and randomized controlled trial (RCT) studies was extracted for pre- and post-treatment systolic, diastolic, and mean arterial blood pressure (SBP, DBP, and MAP). Data Synthesis: A total of 7 studies that enrolled 399 participants met the inclusion criteria. The pooled estimate of mean changes and the corresponding 95% CIs for SBP, DBP, and MAP from each trial are -2.7 mm Hg (95% CI: -0.8 to -4.6), p-value 0.04; -2.7 mm Hg (95% CI: -0.9 to -4.6), p-value 0.004; and -2.40 mm Hg (95% CI: -4.01 to -0.80), p-value 0.003 (Figures 2-4). The pooled estimate of mean changes and the corresponding 95% CIs for nocturnal SBP, DBP, and MAP from each trial are -2.0 mm Hg (95% CI: 1.1 to -5.3), p-value 0.212; -1.7 mm Hg (95% CI: -0.1 to -3.2), p-value 0.03; and -1.9 mm Hg (95% CI: 1.3 to -5.1), p-value 0.255 (Figures 5-7) respectively. Conclusions: The pooled estimate shows a favorable effect of OAs on SBP, MAP, and DBP. Most of the studies were observational. Therefore, more RCTs are warranted involving a larger number of patients and longer treatment periods to confirm the effects of OA on BP.

References Powered by Scopus

Meta-analysis of observational studies in epidemiology: A proposal for reporting

17700Citations
N/AReaders
Get full text

The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults

8893Citations
N/AReaders
Get full text

Prospective study of the association between sleep-disordered breathing and hypertension

4248Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Obstructive sleep apnoea syndrome

806Citations
N/AReaders
Get full text

Obstructive Sleep Apnea and Cardiovascular Disease: A Scientific Statement from the American Heart Association

653Citations
N/AReaders
Get full text

CPAP vs mandibular advancement devices and blood pressure in patients with obstructive sleep apnea a systematic review and meta-analysis

281Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Iftikhar, I. H., Hays, E. R., Iverson, M. A., Magalang, U. J., & Maas, A. K. (2013). Effect of oral appliances on blood pressure in obstructive sleep apnea: A systematic review and meta-analysis. Journal of Clinical Sleep Medicine. https://doi.org/10.5664/jcsm.2420

Readers over time

‘13‘14‘15‘16‘17‘18‘19‘20‘21‘22‘23‘2409182736

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 51

61%

Researcher 16

19%

Professor / Associate Prof. 12

14%

Lecturer / Post doc 4

5%

Readers' Discipline

Tooltip

Medicine and Dentistry 88

84%

Nursing and Health Professions 7

7%

Agricultural and Biological Sciences 6

6%

Psychology 4

4%

Save time finding and organizing research with Mendeley

Sign up for free
0