Background: A single-bolus non-ECG-triggered method was previously proposed to reduce the complexity of quantitative myocardial perfusion imaging [1]. Compared to conventional dual-bolus method, the arterial input function (AIF) is derived from imaging data, eliminating the need for an additional scan. The imaging workflow is further simplified by retrospectively determining the proper reconstruction window, eliminating the dependency on ECG triggering. However, only a single slice was acquired. In this work, we expand upon the previous technique to 3 slices using highly constrained back projection (HYPR) reconstruction to achieve clinically acceptable myocardial coverage. Methods: Data was acquired continuously with no ECG-triggering. 26 projections per slice were acquired following each SR-preparation in an interleaved manner. HYPR was used to reconstruct images with 5-fold undersampling. A sliding window was used to produce series of low resolution images in the basal slice with a temporal resolution of 44 ms. Triggering signal was derived retrospectively from the mean signal intensity in an ROI drawn around the heart. AIF was estimated using single-cardiac cycle T1 mapping [1]. In short low resolution images reconstructed from subsets of projections are used to sample the T1 relaxation. The image signal intensities of the ventricular blood pool are then fit to the Bloch equation to solve for T1. T1 values are then converted to contrast agent concentrations. Ten healthy volunteers underwent rest perfusion MRI on a Siemens 3T Verio. A dual-bolus protocol was performed using a conventional clinical Cartesian sequence for comparison [3]. Ten minutes following the dualbolus scan, a second first-pass scan was performed using the proposed method. The mean myocardial blood flow (MBF) in each subject was compared using a two-sided Student's t-test at a p=0.05 significance level. In a 2nd study, another 12 healthy volunteers underwent stress-rest studies using the proposed method. Mean myocardial perfusion reserve (MPR) was compared with previously published values. Results: Mean MBF values found using the ECG-triggered dual-bolus method and the non-ECG-triggered integrated T1 mapping method were 0.82 ± 0.21 and 0.76 ± 0.13 ml/min/g, respectively. There was no significant difference (p = 0.45) between them. The mean rest and stress MBF and MPR was 0.86±0.5, 3.91±1.1 ml/min/g, and 4.31±1.3, respectively. Conclusions: A 3-slice, non-ECG-triggered, single-bolus quantitative perfusion MR method with integrated T1 mapping for AIF measurement produces similar MBF as the reference dual-bolus method with comparable ventricular coverage. Mean MPR is similar to those reported in literature. The proposed non-ECG-triggered technique improves ease-of-use, and has the potential to improve robustness to arrhythmias. This method may improve the clinical feasibility of quantitative myocardial perfusion imaging. (Figure Presented).
CITATION STYLE
Chen, D., Sharif, B., Wei, J., Bi, X., Arsanjani, R., Thomson, L. E., … Li, D. (2015). Three slice myocardial coverage using non-ECG-triggered perfusion imaging with integrated T1 mapping for quantifying myocardial blood flow. Journal of Cardiovascular Magnetic Resonance, 17, Q61. https://doi.org/10.1186/1532-429x-17-s1-q61
Mendeley helps you to discover research relevant for your work.