Background: The Supercapsular percutaneously assisted total hip (SuperPath) technique is a relatively new minimally invasive approach for total hip arthroplasty (THA). Good clinical outcomes related to its use are reported in the literature. Nonetheless, there are still uncertainties about its validity in terms of radiographic outcomes. Main purpose of the study is to evaluate the effectiveness of the SuperPath in acetabular cup positioning through radiographic evaluation of acetabular inclination angle (IA) and acetabular anteversion (AA) angle within the safe zone described by Lewinnek. The leg length discrepancy (LLD), femoral offset (FO), and acetabular offset (AO) were also measured to ascertain the radiographic effectiveness of SuperPath in the acetabular cup placement. Methods: Between January 2016 and December 2019, all SuperPath cases eligible for the study were included. They were operated by three orthopaedic surgeons with long-standing experience in THA via conventional posterolateral approach and who have performed SuperPath training fellowship. The Mann-Whitney U test was used for statistical assessments (p-value < 0.05). Means ± standard deviation (SD) of the radiographic IA and AA were calculated for each year. Results: A retrospective analysis of 756 THAs was performed. The average percentage of IA within the Lewinnek’s safe zone was from 80 to 85%, while the average percentage of AA was from 76 to 79%. Both IA and AA showed no statistically significant difference between two consecutive years. Good results, in the ranges of normal values, were also obtained for LLD, FO and AO, with homogeneous outcomes between 1 year and the following one. Conclusion: It is possible to achieve good radiographic values of acetabular cup orientation through the SuperPath within the Lewinnek’s safe zone. These results are similar to those reported in the literature by authors using SuperPath. Low rate (0,3%) of hip dislocations were reported. Therefore, the SuperPath technique represents a good alternative THA approach. Nevertheless, there is not a statistically significant improvement in these radiographic parameters over a four-year time. Level of evidence: Level IV, retrospective study.
CITATION STYLE
Di Maro, A., Creaco, S., Albini, M., Latiff, M., & Merlo, M. (2022). Radiographic results on acetabular cup placement with the SuperPath technique: a retrospective study of 756 cases. BMC Musculoskeletal Disorders, 23(1). https://doi.org/10.1186/s12891-022-05065-7
Mendeley helps you to discover research relevant for your work.