Diagnostic performance of 18F-PSMA-1007 PET/CT in patients with biochemical recurrent prostate cancer

98Citations
Citations of this article
113Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: The introduction of ligands targeting prostate-specific membrane antigen (PSMA), especially 68Ga-PSMA-11, has changed the management of patients with prostate cancer (PCa). 18F-Labelled ligands can be produced in larger amounts and therefore can improve availability for a larger group of patients. The aim of this study was to evaluate the diagnostic performance of the recently introduced 18F-PSMA-1007 in patients with recurrent PCa. Methods: This retrospective analysis included 100 consecutive patients with biochemical relapse (mean age 68.75 ± 7.6 years) referred for PSMA PET/CT. Whole-body PET/CT imaging (from the lower limbs to the skull) was performed in all patients 120 min after injection of 338 ± 44.31 MBq 18F-PSMA-1007. Prostatectomy, radiation beam therapy of the prostate bed and androgen-deprivation therapy had been performed in 92%, 45% and 27% of the patients, respectively. Radiation beam therapy of the prostate bed had been performed in addition to surgery in 38 patients (38%) and 10 patients (10%) had received all three therapy modalities. The probability of a 18F-PSMA-1007 PET/CT scan suggestive of pathology was compared with the Gleason score (GS) and PSA level. Results: Of the 100 patients, 95 (95%) showed at least one pathological finding on 18F-PSMA-1007 PET/CT. The overall median PSA level was 1.34 ng/ml (range 0,04–41.3 ng/ml). The rates of pathological scans were 86%, 89%, 100% and 100% among patients with PSA levels ≤0.5, 0.51–1.0, 1.1–2.0 and > 2.0 ng/ml, respectively. The median GS was 7 (range 5–10). The majority of patients (70) with a GS available had a score in the range 7–9. The rate of pathological scans in these patients was 93% (65/70). The median SUVmax values of the pathological findings were 10.25, 14.32, 13.16 and 28.87 in patients with PSA levels ≤0.5, 0.51–1.0, 1.1–2.0 and >2.0 ng/ml, respectively. The median SUVmax in patients with a PSA level of >2.0 ng/ml was significantly higher than in all other PSA groups. Conclusion: 18F-PSMA-1007 PET/CT can detect recurrent PCa in a high percentage of patients with biochemical relapse. The probability of a pathological 18F-PSMA-1007 PET/CT scan seems to be high even in patients with a low PSA level ≤0.5 ng/ml, and this may have a significant impact on the management of this relevant group of patients.

Cite

CITATION STYLE

APA

Rahbar, K., Afshar-Oromieh, A., Seifert, R., Wagner, S., Schäfers, M., Bögemann, M., & Weckesser, M. (2018). Diagnostic performance of 18F-PSMA-1007 PET/CT in patients with biochemical recurrent prostate cancer. European Journal of Nuclear Medicine and Molecular Imaging, 45(12), 2055–2061. https://doi.org/10.1007/s00259-018-4089-x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free