FBPA PET in boron neutron capture therapy for cancer: Prediction of 10B concentration in the tumor and normal tissue in a rat xenograft model

58Citations
Citations of this article
68Readers
Mendeley users who have this article in their library.

Abstract

Background: Boron neutron capture therapy (BNCT) is a molecular radiation treatment based on the 10B (n, α) 7Li nuclear reaction in cancer cells, in which delivery of 10B by 4-borono-phenylalanine conjugated with fructose (BPA-fr) to the cancer cells is of critical importance. The PET tracer 4-borono-2-18 F-fluoro-phenylalanine (FBPA) has been used to predict the accumulation of BPA-fr before BNCT. However, because of the difference in chemical structure between BPA-fr and FBPA and the difference in the dose administered between BPA-fr (therapeutic dose) and FBPA (tracer dose), the predictive value of FBPA PET for BPA-fr accumulation in the tumor and normal tissues is not yet clearly proven. We conducted this study to validate FBPA PET as a useful test to predict the accumulation of BPA-fr in the tumor and normal tissues before BNCT. Methods: RGC-6 rat glioma cells (1.9 × 107) were implanted subcutaneously in seven male F344 rats. On day 20 after the tumor implantation, dynamic PET scan was performed on four rats after injection of FBPA for 1 h. Whole-body PET/CT was performed 1 h after intravenous injection of the FBPA solution (30.5 ± 0.7 MBq, 1.69 ± 1.21 mg/kg). PET accumulation of FBPA in the tumor tissue and various normal tissues was estimated as a percentage of the injected dose per gram (%ID/g). One hour after the PET/CT scan, BPA-fructose (167.32 ± 18.65 mg/kg) was injected intravenously, and the rats were dissected 1 h after the BPA-fr injection. The absolute concentration of 10B in the autopsied tissues and blood was measured by inductively coupled plasma optical emission spectrometry (ICP-OES). Results: The highest absolute concentration of 10B determined by ICP-OES was found in the kidney (4.34 ± 0.84 %ID/g), followed by the pancreas (2.73 ± 0.63 %ID/g), and the tumor (1.44 ± 0.44 %ID/g). A significant positive correlation was found between the accumulation levels of BPA-fr and FBPA (r = 0.91, p < 0.05). Conclusions: FBPA PET can reliably predict accumulation of BPA-fr in the tumor as well as normal tissues.

Cite

CITATION STYLE

APA

Hanaoka, K., Watabe, T., Naka, S., Kanai, Y., Ikeda, H., Horitsugi, G., … Hatazawa, J. (2014). FBPA PET in boron neutron capture therapy for cancer: Prediction of 10B concentration in the tumor and normal tissue in a rat xenograft model. EJNMMI Research, 4(1). https://doi.org/10.1186/s13550-014-0070-2

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free