Online parameter determination based adaptive single-phase reclosing scheme for wind-powered outgoing lines with shunt reactors

13Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

As the only power output channel of wind farms, wind-powered outgoing lines carry the risk of reclosing to faults as an applied single-phase reclosing scheme recloses the outgoing line after a fixed time without distinguishing transient and permanent faults. Although various transient-fault identification (TFI) methods were proposed for conventional power transmission lines with shunt reactors, they can be hardly utilised on wind-powered outgoing lines with shunt reactors due to the influence of outgoing line complex working conditions and wind farms inconsistent output power. In this study, reactive power was calculated using the instantaneous power algorithm to obtain the equivalent reactance of the outgoing line faulty phase shunt reactor. Then, a TFI method for the outgoing lines with shunt reactors based on online parameter determination was proposed, a relevant adaptive single-phase auto-reclosing (ASPAR) scheme was established. Finally, the validity and feasibility of the proposed TFI method and ASPAR scheme were verified by conducting simulation experiments on the software PSCAD/EMTDC. The experiments confirmed that the proposed ASPAR scheme can achieve immunity to changes in fault location and transition resistance, and are therefore suitable for inconsistent output power of wind farms and complex working conditions of outgoing lines.

References Powered by Scopus

New digital algorithm for adaptive reclosing based on the calculation of the faulted phase voltage total harmonic distortion factor

118Citations
N/AReaders
Get full text

New approach to adaptive single pole auto-reclosing of power transmission lines

79Citations
N/AReaders
Get full text

A noncommunication adaptive single-pole autoreclosure scheme based on the acusum algorithm

60Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Three-Phase Adaptive Auto-Reclosing for Single Outgoing Line of Wind Farm Based on Active Detection from STATCOM

26Citations
N/AReaders
Get full text

Adaptive Comprehensive Auto-Reclosing Scheme for Shunt Reactor-Compensated Transmission Lines

19Citations
N/AReaders
Get full text

Adaptive reclosure scheme of MMC-HVDC transmission lines using additional capacitors

10Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Xie, C., & Li, F. (2019). Online parameter determination based adaptive single-phase reclosing scheme for wind-powered outgoing lines with shunt reactors. IET Renewable Power Generation, 13(8), 1317–1328. https://doi.org/10.1049/iet-rpg.2018.5358

Readers' Seniority

Tooltip

Professor / Associate Prof. 2

67%

PhD / Post grad / Masters / Doc 1

33%

Readers' Discipline

Tooltip

Engineering 3

100%

Save time finding and organizing research with Mendeley

Sign up for free