Patent foramen ovale and left atrial appendage flow velocity predict atrial fibrillation recurrence post cryoballoon ablation

12Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

Abstract

Background: Transesophageal echocardiography (TEE) allows detailed characterization of atrial fibrillation (AF) substrate and could be valuable for predicting pulmonary vein isolation (PVI) procedure outcomes. Aims: We aimed at assessing the value of TEE-derived left atrial (LA) and LA appendage (LAA) features as prognostic markers for AF recurrence after cryoballoon-based ablation. Methods: Patients were enrolled using a prospective database of consecutive PVI procedures performed over a 7-year period. The following TEE-derived parameters were investigated: LAA emptying flow velocity (LAA-FV), the presence of patent foramen ovale (PFO), LA spontaneous echo contrast, and mitral regurgitation. Diagnosis of AF recurrence was based on scheduled and symptoms triggered ECG monitoring. The Cox's regression model and Kaplan-Meier survival curves were applied for statistical analysis. Results: A total of 417 consecutive patients who underwent their first PVI using cryoballoon were analyzed (mean age: 59 years). AF recurrence was noted in 25.7% of patients (median follow-up of 24 months). Four TEE-derived variables had predictive values for AF recurrence: LAA-FV <45 cm/s, presence of PFO at resting state, LA spontaneous echo contrast, and mitral regurgitation. In the multivariable model, apart from the transthoracic echocardiography-derived LA size, two TEE-derived features (LAA-FV <45 cm/s and the presence of PFO) remained as independent predictors. Conclusions: This study proposed a novel TEE-derived AF recurrence risk factor - the presence of PFO - and confirmed the prognostic value of LAA flow velocity in patients undergoing cryoballoon-based AF ablation. These risk factors could be useful in the global assessment of AF recurrence risk and potentially helpful in planning the ablation strategy.

Cite

CITATION STYLE

APA

Kiełbasa, G., Bednarek, A., Bednarski, A., Olszanecka, A., Sondej, T., Kusiak, A., … Jastrzȩbski, M. (2021). Patent foramen ovale and left atrial appendage flow velocity predict atrial fibrillation recurrence post cryoballoon ablation. Kardiologia Polska, 79(8), 756–764. https://doi.org/10.33963/KP.a2021.0004

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free