Background: Accurate preoperative planning for total hip arthroplasty (THA) relies on conventional anteroposterior radiographs. The difficulty of determining the magnification factor of radiographs is a major limitation. Despite the use of markers for calibration, identifying the plane of the hip joint is a major challenge. The aim of this study was to evaluate the accuracy of a novel method for image calibration and preoperative planning in THA involving the use of a biplanar radiographic (EOS imaging) system and a self-designed coin device. Methods: Biplanar radiographs (with the self-designed coin device) and a conventional anteroposterior radiograph (with a coin) were made for 26 patients after primary THA. The agreement between the actual and calculated diameters for each method was assessed using the concordance correlation coefficient (CCC) and Bland-Altman plots. In addition, 15 patients undergoing primary THA were prospectively enrolled to evaluate the EOS imaging-based method (EOS method), with biplanar radiographs made with use of the coin device. The accuracy of the preoperative predicted size of the implants was evaluated. Results: Both the EOS and conventional anteroposterior radiograph-based methods were reliable in repeated measurements of the diameter of the artificial femoral head in the reproducibility study, with the average CCCs for both methods >0.990. The agreement between the actual and EOS-based calculated diameters of the artificial femoral head was excellent, with a CCC of >0.990, while the agreement was poor between the actual and anteroposterior radiograph-based calculated diameters, with a CCC of <0.75. The EOS method exhibited a lower absolute difference (0.09 ± 0.07 mm) between the actual and calculated diameters compared with conventional anteroposterior radiography (1.26 ± 0.86 mm) (p < 0.001). EOS-based preoperative plans also exhibited excellent performance on the accuracy of the planning of the cups and stems; only 1 patient (6.7%) had a final implanted cup that differed by 1 size from the predicted size. Two patients (13.3%) had final implanted stems that differed by 1 size from the predicted size, and for 1 patient (6.7%), the stem size was off by ‡2 sizes. Conclusions: We describe a novel and easy-to-use method for the accurate calibration of radiographs and preoperative planning for THA. The EOS method evaluated in this study is an alternative method for preoperative planning in clinical practice.
Mendeley helps you to discover research relevant for your work.
CITATION STYLE
Huang, J., Zhu, Y., Ma, W., Zhang, Z., Shi, W., & Lin, J. (2020). A Novel Method for Accurate Preoperative Templating for Total Hip Arthroplasty Using a Biplanar Digital Radiographic (EOS) System. JBJS Open Access, 5(4), E2000078. https://doi.org/10.2106/JBJS.OA.20.00078