Consistent posttest calculations for LOCA scenarios in LOBI integral facility

6Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

Abstract

Integral test facilities (ITFs) are one of the main tools for the validation of best estimate thermalhydraulic system codes. The experimental data are also of great value when compared to the experiment-scaled conditions in a full NPP. The LOBI was a single plus a triple-loop (simulated by one loop) test facility electrically heated to simulate a 1300MWe PWR. The scaling factor was 712 for the core power, volume, and mass flow. Primary and secondary sides contained all main active elements. Tests were performed for the characterization of phenomenologies relevant to large and small break LOCAs and special transients in PWRs. The paper presents the results of three posttest calculations of LOBI experiments. The selected experiments are BL-30, BL-44, and A1-84. They are LOCA scenarios of different break sizes and with different availability of safety injection components. The goal of the analysis is to improve the knowledge of the phenomena occurred in the facility in order to use it in further studies related to qualifying nodalizations of actual plants or to establish accuracy data bases for uncertainty methodologies. An example of procedure of implementing changes in a common nodalization valid for simulating tests occurred in a specific ITF is presented along with its confirmation based on posttests results. Copyright © 2012 F. Revents et al.

References Powered by Scopus

Outline of the uncertainty methodology based on accuracy extrapolation

140Citations
N/AReaders
Get full text

Development of a code with the capability of internal assessment of uncertainty

137Citations
N/AReaders
Get full text

Advanced qualification process of ANAV NPP integral dynamic models for supporting plant operation and control

21Citations
N/AReaders
Get full text

Cited by Powered by Scopus

The use of system codes in scaling studies: Relevant techniques for qualifying NPP nodalizations for particular scenarios

19Citations
N/AReaders
Get full text

Preservation and use of integral system test facilities data: The experience of the LOBI data and the STRESA database

7Citations
N/AReaders
Get full text

Applications of SYS TH codes to nuclear reactor design and accident analysis

3Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Reventós, F., Pla, P., Matteoli, C., Nacci, G., Cherubini, M., Del Nevo, A., & D’Auria, F. (2012). Consistent posttest calculations for LOCA scenarios in LOBI integral facility. Science and Technology of Nuclear Installations, 2012. https://doi.org/10.1155/2012/474162

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

43%

Researcher 5

36%

Professor / Associate Prof. 3

21%

Readers' Discipline

Tooltip

Engineering 7

58%

Energy 4

33%

Environmental Science 1

8%

Save time finding and organizing research with Mendeley

Sign up for free