The Sm:YAG primary fluorescence pressure scale

39Citations
Citations of this article
36Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Primary pressure determinations involve the measurement of pressure without recourse to secondary standard materials. These measurements are essential for ensuring the accuracy of pressures measured in gasketed high-pressure devices. In this study, the wavelength of optical fluorescence bands and the density of single crystal Sm-doped yttrium aluminum garnet Y3Al 5O12 (Sm:YAG) have been calibrated as a primary pressure scale up to 58 GPa. Absolute pressures were obtained by integrating the bulk modulus determined via Brillouin spectroscopy with respect to volumes measured simultaneously by X-ray diffraction. A third-order Birch-Murnaghan equation of state of Sm:YAG yields V0 = 1735.15(26) Å3, K T0 = 185(1.5) GPa, and K' = 4.18(5). The accompanied pressure-induced shifts of the fluorescence lines Y1 and Y2 of Sm:YAG were calibrated to the primary pressure, thus creating a highly accurate fluorescence pressure scale. These shifts are described as P = (A/B) * {[1 + (Δλ/ λ0)]B - 1} with A = 2089.91(23.04), B = -4.43(1.07) for Y1, and A = 2578.22(48.70), B = -15.38(1.62) for Y2 bands, where â̂†λ = λ - λ0, λ and λ0 are wavelengths in nanometer at pressure and ambient conditions. The sensitivity in the pressure determination of the Sm:YAG fluorescence shift is 0.32 nm/GPa, which is identical to that of the ruby scale. Sm:YAG can be considered elastically isotropic up to 58 GPa, implying insensitivity of the determined pressure to the crystallographic orientation under nonhydrostatic or quasi-hydrostatic conditions. The Sm:YAG fluorescence shift is apparently also independent of crystallographic orientation, in contrast to that of ruby. Since the Y fluorescence band of Sm:YAG is insensitive to temperature changes, this material is highly suitable for the measurement of pressure at elevated temperatures. Key Points Elastically isotropic fluorescence pressure sensor Static primary fluorescence pressure scale Ensuring the accuracy of pressures measured in gasketed high pressure devices ©2013. American Geophysical Union. All Rights Reserved.

Cite

CITATION STYLE

APA

Trots, D. M., Kurnosov, A., Ballaran, T. B., Tkachev, S., Zhuravlev, K., Prakapenka, V., … Frost, D. J. (2013). The Sm:YAG primary fluorescence pressure scale. Journal of Geophysical Research: Solid Earth, 118(11), 5805–5813. https://doi.org/10.1002/2013JB010519

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free