Performance of loop-mediated isothermal amplification assay in the diagnosis of pulmonary tuberculosis in a high prevalence TB/HIV rural setting in Uganda

18Citations
Citations of this article
88Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Smear microscopy lacks sensitivity especially in HIV co-infection, resulting in undiagnosed tuberculosis (TB) and high mortality. The loop-mediated isothermal amplification (TB-LAMP) assay can be staged with minimal infrastructure, is rapid, low cost and detection can be with the naked eye. We assessed feasibility and performance of Eiken TB-LAMP test at point-of-need in TB diagnosis in a high prevalence TB/HIV rural setting in Uganda. Methods: From October 2013-February 2014, TB-LAMP testing was performed on sputum specimens from outpatient presumptive TB adults at a district hospital and two low-level health centers in Kiboga District where smear microscopy is the available routine diagnostic option. TB-LAMP was performed by a technician after a week of training in the district hospital. The technician had no prior experience in the technology. Samples from the low-level health centers were transported to the district hospital for TB-LAMP. Results: Of the 233 presumptive TB (126 at hospital); 113 (48.5%) were HIV-infected; 129 (55%) male, median age 40 (IQR 30-53). Compared to MTB culture, overall sensitivity and specificity of TB-LAMP were 55.4% (95 CI 44.1-66.3) and 98.0% (95 CI 94.3-99.6) respectively. Among HIV-infected participants, TB-LAMP sensitivity and specificity were 52.3% (95 CI 36.7-67.5%) and 97.1% (95 CI 89.9-99.6) respectively; and 24.4% (95% CI 12.9-39.5) and 98.6% (95% CI 95.1-99.8) respectively among smear-negatives. TB-LAMP sensitivity and specificity were 62.2% (95% CI 44.8-77.5) and 97.8% (95% CI 92.1-99.7) in the hospital setting where central testing occurred compared to 50.0% (95% CI 34.9-65.1) and 98.4% (95% CI 91.2-100) respectively in low-level health centers where specimens were transported centrally. Conclusions: In this high prevalence TB/HIV rural setting, TB-LAMP performs better than conventional smear microscopy in diagnosis of MTB among presumptive TB patients although the sensitivity is lower than that reported by the World Health Organization. TB-LAMP can easily be performed following a short training period and in absence of sophisticated infrastructure and expertise.

Cite

CITATION STYLE

APA

Nakiyingi, L., Nakanwagi, P., Briggs, J., Agaba, T., Mubiru, F., Mugenyi, M., … Manabe, Y. C. (2018). Performance of loop-mediated isothermal amplification assay in the diagnosis of pulmonary tuberculosis in a high prevalence TB/HIV rural setting in Uganda. BMC Infectious Diseases, 18(1). https://doi.org/10.1186/s12879-018-2992-1

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free