Clinical and functional outcomes of a novel transosseous device to treat rotator cuff tears: A minimum 2-year follow-up

2Citations
Citations of this article
54Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: Despite the improvements in the repair equipment techniques of rotator cuff, a gold standard method has not been defined yet and transosseous fixation through deltoid-splitting (mini-open) approach is still regarded as a good option. The primary purpose of this study is to present satisfactory clinical and functional outcomes with a novel transosseous device in full-thickness rotator cuff tear through deltoid-splitting. Materials and Methods: This retrospective study was performed on 70 consecutive patients who underwent surgery by a single surgeon from June 2014 to June 2016 for a full-thickness rotator cuff tear and was managed with a novel transosseous device. Total number of patients, mean age, percentage of male and female patients, mean duration of follow-up, percentage of involvement of the dominant extremity, affected shoulder, and tear size were recorded. Functional and clinical outcomes were assessed baseline and postoperatively at 3 and 6 months and final follow-up using Disabilities of the Arm, Shoulder and Hand (Q-DASH) and Constant-Murley scores. Results: A total of 70 (49 (70%) female, 21 (30%) male) patients whose mean age was 58.66 ± 9.19 (38–77) years were included. The mean surgery time was 35.33 ± 5.34 (28–55) min. The mean follow-up time was 28.31 ± 3.03 (24–36) months. According to the DeOrio and Cofield classification, 15 (21.43%) tears were small, 33 (47.14%) medium, 16 (22.86%) large, and 6 (8.57%) massive. By the final follow-up, the mean Constant-Murley score had significantly improved from 27.67 ± 7.46 (13–41) to 81.25 ± 3.77 (74–87; p = 0.0001) and the Q-DASH score had decreased from 82.34 ± 10.37 (65.91–100) to 10.28 ± 6.88 (0–23.45; p = 0.0001). There were no significant differences in the Constant-Murley or Q-DASH score at baseline–final follow-up between the small, medium, large, and massive tear groups (p > 0.05). Conclusions: Treatment of full-thickness rotator cuff tear using this novel transosseous device significantly improved functional and clinical scores. However, further long-term prospective randomized multicenter trials involving comparative studies are necessary to confirm these findings.

Cite

CITATION STYLE

APA

Arican, M., Turhan, Y., Karaduman, Z. O., & Ayanoğlu, T. (2019). Clinical and functional outcomes of a novel transosseous device to treat rotator cuff tears: A minimum 2-year follow-up. Journal of Orthopaedic Surgery, 27(3). https://doi.org/10.1177/2309499019875172

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free