The performance of the chemiluminescent immunoassay for measuring serum myeloperoxidase and proteinase 3 antibodies

1Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Enzyme-linked immunosorbent assay (ELISA) has traditionally been used to detect myeloperoxidase (MPO) and proteinase 3 (PR3) antibodies, although it is time-consuming and physically demanding. As a novel and highly effective immunoassay, we compared chemiluminescent immunoassay (CIA) with ELISA to verify the application value of CIA in MPO and PR3 antibodies detection. Methods: By ELISA and CIA, serum levels of anti-MPO and anti-PR3 antibodies were measured in 63 anti-neutrophil cytoplasmic antibody (ANCA)-associated vasculitis (AAV) patients (AAV group), including 47 microscopic polyangiitis (MPA) patients and 16 granulomatosis with polyangiitis (GPA) patients, in addition, 68 patients in interference control group (IC group), 19 healthy subjects in healthy control group (HC group). We compared MPO and PR3 antibodies levels and positive rates measured by these two methods among groups. Relationship and coincidence rate between ELISA and CIA were investigated. Diagnostic values for clinical outcomes for MPO and PR3 antibodies were assessed by receiver operator characteristic (ROC) curve. Results: In AAV patients, when detecting anti-MPO (r =.90) and anti-PR3 (r =.81), CIA was highly correlated with ELISA, companying with highly total (88.89%, 92.06%, respectively) and positive coincidence rates (84.78%, 77.27%, respectively). In HC group, anti-PR3 positive rate detected by both immunoassay were 0, anti-MPO almost were 0, which without statistically significant difference (P =.32). In IC group, the total (76.47%, 58.82, respectively) and positive coincidence rates (48.38%, 30.00%, respectively) of anti-MPO and anti-PR3 were the lowest, but the negative coincidence rates reached 100%. By CIA, similar to ELISA, the levels of anti-MPO were significantly higher both in AAV patients (56.00; [4.40-235.30]) and MPA patients (98.00; [27.90-324.70]) compared with either IC group (3.20; [3.20-18.55) (P

Cite

CITATION STYLE

APA

Hou, X., Liu, J., Wang, T., Zhou, J., & Cui, L. (2021). The performance of the chemiluminescent immunoassay for measuring serum myeloperoxidase and proteinase 3 antibodies. Journal of Clinical Laboratory Analysis, 35(2). https://doi.org/10.1002/jcla.23615

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free