Phantom model and scoring system to assess ability in ultrasound-guided chest drain positioning

18Citations
Citations of this article
57Readers
Mendeley users who have this article in their library.

Abstract

Background: Chest tube positioning is an invasive procedure associated with potentially serious injuries. In the last few years, we have been running a project directed at developing a practical simulator of a surgical procedure taught on our medical training program. The phantom model reconstructs the pleural anatomy, visible by lung ultrasound, used for the assessed performance of the Seldinger technique. The aim of the present study was to investigate the validity of this simulation technology for assessing residents in anesthesia and intensive care medicine; specifically, their skill in positioning a US-guided chest tube drain was tested using the simulator device. The second aim of the paper was to evaluate the learning curve of our residents over their 5-year study course and validate the phantom scoring system. Methods: This was a prospective, single-blinded observational study. Participants were recruited from residents in anesthesia and intensive care medicine and divided into two groups: ‘Novice’ and ‘Expert,’ based on the course year attended (years 1, 2, and 3 vs. years 4 and 5, respectively). We asked them to position a chest tube drain in a phantom model, guided by ultrasound, to drain a simulated pleural effusion. Each subject performed two tests that simulated pleural effusions of 4 and 2 cm, respectively. Every step of the maneuver was constantly monitored and the performance scored by the investigators. We then performed a Spearman correlation analysis to evaluate the effect of experience level on the performance of the two groups of residents. Results: Thirty-one residents were included in this study: 20 in the Novice group and 11 in the Expert group. The mean performance rating score was 0.75 ± 4.38 for the Novice Group and 5.91 ± 3.75 for the Expert group (p = 0.0026). The Spearman correlation analysis examining the relationship between year of residency and performance rating score confirmed a positive correlation (r = 0.58, p = 0.0006). Post-test trend analysis revealed a statistically significant linear trend for skill growth across time, i.e., course year (p = 0.0022). Conclusions: Our simulated procedure using a phantom model of lung anatomy can accurately and reliably be used to assess the skill levels of operators in their ability to drain pleural effusion.

Figures

  • Fig. 1 The thoracentesis simulator ‘Ultrasound Thoracentesis Model THM-30’ developed by SIMULAB, Seattle, USA. It features a partial torso with anatomical landmarks, such as skin texture, ribs, and a fluid reservoir. Its simulated lung is seen as an echogenic structure with an
  • Fig. 3 Performance rating score for the Novice and Expert groups. The colored boxes extend from the 25th to 75th percentiles. The whiskers indicate the minimum and maximum values. The plus signs indicate the mean value. p = 0.0026
  • Table 1 Distribution of  study subjects by  residency year and mean performance rating scores
  • Table 2 Correlation analysis examining the relationship between year of residency and performance rating score
  • Table 3 Main complications occurred
  • Fig. 4 Mean performance rating score in residents subdivided by year. Error bars represent standard deviations. The development of residents’ skills in pleural effusion ultrasound and chest drain positioning appears to progress steadily with increasing years of residency, reaching a plateau in the last 2 years. p = 0.025

Cited by Powered by Scopus

This article is free to access.

This article is free to access.

24Citations
98Readers

This article is free to access.

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Vetrugno, L., Volpicelli, G., Barbariol, F., Toretti, I., Pompei, L., Forfori, F., & Della Rocca, G. (2016). Phantom model and scoring system to assess ability in ultrasound-guided chest drain positioning. Critical Ultrasound Journal, 8(1), 1–7. https://doi.org/10.1186/s13089-016-0038-8

Readers over time

‘16‘17‘18‘19‘20‘21‘22‘23‘24‘250481216

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 21

72%

Researcher 6

21%

Professor / Associate Prof. 2

7%

Readers' Discipline

Tooltip

Medicine and Dentistry 23

72%

Engineering 4

13%

Nursing and Health Professions 3

9%

Agricultural and Biological Sciences 2

6%

Article Metrics

Tooltip
Social Media
Shares, Likes & Comments: 142

Save time finding and organizing research with Mendeley

Sign up for free
0