Non-contact oxygen saturation monitoring for wound healing process using dual-wavelength simultaneous acquisition imaging system

8Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Here we report the fabrication of a noncontact pulse oximeter system based on a dual-wavelength imaging system and its oxygen saturation monitoring performance during wound healing. The dual-wavelength imaging system consists of 660 nm and 940 nm light-emitting diodes and a multi-spectral camera that simultaneously accepts visible and near-infrared images. Using the proposed system, images were acquired at 30 fps at both wavelengths, and photoplethysmography signals were extracted by specifying a specific region in the images. We removed the signals caused by small movements and smoothed them using the discrete wavelet transform and moving average filter. To confirm the feasibility of the proposed noncontact oxygen saturation system, a wound model was created using a hairless mouse and oxygen saturation was measured during wound healing. The measured values were compared and analyzed using a reflective animal pulse oximeter. Through a comparative analysis of these two devices, the error of the proposed system was evaluated and the possibility of its clinical application and wound healing monitoring through oxygen saturation measurement confirmed.

References Powered by Scopus

Understanding Bland Altman analysis

2836Citations
N/AReaders
Get full text

Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults

192Citations
N/AReaders
Get full text

Current progress of photoplethysmography and SPO<inf>2</inf> for health monitoring

178Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Ninety years of pulse oximetry: history, current status, and outlook

4Citations
N/AReaders
Get full text

Multispectral Imaging-Based System for Detecting Tissue Oxygen Saturation With Wound Segmentation for Monitoring Wound Healing

2Citations
N/AReaders
Get full text

Dual-wavelength twin-pulse laser with tunable intensity and delay at 912 nm & 1064 nm under intracavity gain-switched pumping

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Park, Y. rim, Shin, Y. kyoung, & Eom, J. B. (2023). Non-contact oxygen saturation monitoring for wound healing process using dual-wavelength simultaneous acquisition imaging system. Biomedical Engineering Letters, 13(3), 455–463. https://doi.org/10.1007/s13534-023-00275-x

Readers over time

‘23‘24‘2502468

Readers' Seniority

Tooltip

Lecturer / Post doc 1

50%

Researcher 1

50%

Readers' Discipline

Tooltip

Engineering 2

50%

Medicine and Dentistry 1

25%

Computer Science 1

25%

Save time finding and organizing research with Mendeley

Sign up for free
0