Battery drain in daily practice and medium-term projections on longevity of cardioverterdefibrillators: An analysis from a remote monitoring database

22Citations
Citations of this article
57Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aims The longevity of generators is a crucial determinant of the cost-effectiveness of therapy with implantable cardioverterdefibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-D). We evaluated the trend of devicemeasured residual battery capacity and longevity projections over 5-year follow-up.We also investigated possible factors associated with battery drain. Methods and results Data from 4851 patients in the European LATITUDEw database who were followed up for a minimum of 3 years were analysed. The factors associated with battery drain (i.e. year-to-year decrease in residual battery capacity), and thus potentially impacting on device longevity, were mainly the pacing parameters in CRT-D devices and the number of shocks delivered and diverted in both ICD and CRT-D (all P < 0.01 on linear regression analysis). Over the first 5 years, the longevity estimates provided by devices showed low intra-patient variability and increased with time. The estimates exceeded 10 years for CRT-Dand 13 and 12 years for single- and dual-chamber ICDs, respectively. In CRT-D patients, the expected patient age on replacement was 80±12 years, and the expected probability of undergoing device replacement was 63±13% for New York Heart Association (NYHA) II patients and 37±16% for NYHA III patients. For comparison, the probabilities of replacing a CRT-D lasting 5 years were 78±8 and 59±13%, respectively (both P, 0.001). Conclusion Battery drain was mainly associated with pacing output in CRT-D devices and with the number of capacitor charges in both ICD and CRT-D devices. The longevity estimates provided by the devices were consistent and conservative. According to these estimates, among CRT-D recipients a low proportion of patients should require device replacement.

Cite

CITATION STYLE

APA

Boriani, G., Ritter, P., Biffi, M., Ziacchi, M., Diemberger, I., Martignani, C., … Gadler, F. (2016). Battery drain in daily practice and medium-term projections on longevity of cardioverterdefibrillators: An analysis from a remote monitoring database. Europace, 18(9), 1366–1373. https://doi.org/10.1093/europace/euv436

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free