Increasing abdominal pressure with and without PEEP: Effects on intra-peritoneal, intra-organ and intra-vascular pressures

22Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Intra-organ and intra-vascular pressures can be used to estimate intra-abdominal pressure. The aim of this prospective, interventional study was to assess the effect of PEEP on the accuracy of pressure estimation at different measurement sites in a model of increased abdominal pressure.Methods: Catheters for pressure measurement were inserted into the stomach, urinary bladder, peritoneal cavity, pulmonary artery and inferior vena cava of 12 pigs. The pressures were recorded simultaneously at baseline, during 10 cm H20 PEEP, external abdominal pressure (7 kg weight) plus PEEP, external abdominal pressure without PEEP, and again under baseline conditions.Results (mean ± SD): PEEP alone increased diastolic pulmonary artery and inferior vena cava pressure but had no effect on the other pressures. PEEP and external abdominal pressure increased intraperitoneal pressure from 6 ± 1 mm Hg to 9 ± 2 mm Hg, urinary bladder pressure from 6 ± 2 mm Hg to 11 ± 2 mm Hg (p = 0.012), intragastric pressure from 6 ± 2 mm Hg to 11 ± 2 mm Hg (all p ≤ 0.001), and inferior vena cava pressure from 11 ± 4 mm Hg to 15 ± 4 mm Hg (p = 0.01). Removing PEEP and maintaining extraabdominal pressure was associated with a decrease in pulmonary artery diastolic but not in any of the other pressures. There was a significant correlation among all pressures. Bias (-1 mm Hg) and limits of agreement (3 to -5 mm Hg) were similar for the comparisons of absolute intraperitoneal pressure with intra-gastric and urinary bladder pressure, but larger for the comparison between intraperitoneal and inferior vena cava pressure (-5, 0 to -11 mm Hg). Bias (0 to -1 mm Hg) and limits of agreement (3 to -4 mm Hg) for pressure changes were similar for all comparisons. Conclusions: Our data suggest that pressure changes induced by external abdominal pressure were not modified by changing PEEP between 0 and 10 cm H20. © 2010 Jakob et al; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Jakob, S. M., Knuesel, R., Tenhunen, J. J., Pradl, R., & Takala, J. (2010). Increasing abdominal pressure with and without PEEP: Effects on intra-peritoneal, intra-organ and intra-vascular pressures. BMC Gastroenterology, 10. https://doi.org/10.1186/1471-230X-10-70

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free