Semi-automatic quantification of 4D left ventricular blood flow

170Citations
Citations of this article
200Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background. The beating heart is the generator of blood flow through the cardiovascular system. Within the heart's own chambers, normal complex blood flow patterns can be disturbed by diseases. Methods for the quantification of intra-cardiac blood flow, with its 4D (3D+time) nature, are lacking. We sought to develop and validate a novel semi-automatic analysis approach that integrates flow and morphological data. Method. In six healthy subjects and three patients with dilated cardiomyopathy, three-directional, three-dimensional cine phase-contrast cardiovascular magnetic resonance (CMR) velocity data and balanced steady-state free-precession long- and short-axis images were acquired. The LV endocardium was segmented from the short-axis images at the times of isovolumetric contraction (IVC) and isovolumetric relaxation (IVR). At the time of IVC, pathlines were emitted from the IVC LV blood volume and traced forwards and backwards in time until IVR, thus including the entire cardiac cycle. The IVR volume was used to determine if and where the pathlines left the LV. This information was used to automatically separate the pathlines into four different components of flow: Direct Flow, Retained Inflow, Delayed Ejection Flow and Residual Volume. Blood volumes were calculated for every component by multiplying the number of pathlines with the blood volume represented by each pathline. The accuracy and inter- and intra-observer reproducibility of the approach were evaluated by analyzing volumes of LV inflow and outflow, the four flow components, and the end-diastolic volume. Results. The volume and distribution of the LV flow components were determined in all subjects. The calculated LV outflow volumes [ml] (67 13) appeared to fall in between those obtained by through-plane phase-contrast CMR (77 16) and Doppler ultrasound (58 10), respectively. Calculated volumes of LV inflow (68 11) and outflow (67 13) were well matched (NS). Low inter- and intra-observer variability for the assessment of the volumes of the flow components was obtained. Conclusions. This semi-automatic analysis approach for the quantification of 4D blood flow resulted in accurate LV inflow and outflow volumes and a high reproducibility for the assessment of LV flow components. © 2010 Eriksson et al; licensee BioMed Central Ltd.

References Powered by Scopus

Asymmetric redirection of flow through the heart

629Citations
N/AReaders
Get full text

Quantitative 2D and 3D phase contrast MRI: Optimized analysis of blood flow and vessel wall parameters

406Citations
N/AReaders
Get full text

Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping

195Citations
N/AReaders
Get full text

Cited by Powered by Scopus

4D flow cardiovascular magnetic resonance consensus statement

686Citations
N/AReaders
Get full text

4D flow MRI

659Citations
N/AReaders
Get full text

Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance

392Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Eriksson, J., Carlhäll, C., Dyverfeldt, P., Engvall, J., Bolger, A., & Ebbers, T. (2010). Semi-automatic quantification of 4D left ventricular blood flow. Journal of Cardiovascular Magnetic Resonance, 12(1). https://doi.org/10.1186/1532-429X-12-9

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 79

54%

Researcher 45

31%

Professor / Associate Prof. 18

12%

Lecturer / Post doc 5

3%

Readers' Discipline

Tooltip

Medicine and Dentistry 59

44%

Engineering 50

38%

Computer Science 18

14%

Physics and Astronomy 6

5%

Save time finding and organizing research with Mendeley

Sign up for free