Wave Detection of Acceleration Plethysmogram Based on a Closed-Loop Feedback Mechanism

  • Ahn* J
  • et al.
N/ACitations
Citations of this article
1Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Acceleration plethysmogram (APG), which corresponds to the second derivative of the photoplethysmogram (PPG) is a noninvasive method for investigating arterial wall thickness and predicting cardiovascular diseases. To perform an APG wave analysis, five inflection points of the APG waveform (a, b, c, d, and e waves) must be successfully obtained. However, an abrupt change in PPG amplitude due to various physiological conditions and patient’s movement has made it very difficult to detect the five waves of the APG waveform in real time. Therefore, to resolve this problem, two stabilization methods for PPG and APG amplitudes were proposed based on a closed-loop feedback amplitude control mechanism. The regulation of PPG amplitude was rapidly carried out in four cardiac cycles by controlling the driving current to a light emitting diode (LED) through pulse width modulation (PWM). Two predetermined amplitude levels were applied to adjust the 1st and the 2nd derivatives of the PPG simultaneously when the wave detection algorithm failed to detect even one of five waves. Forty measurements of the APG signal on an index fingertip were performed to verify a closed-loop feedback amplitude control mechanism (CLFACM). The values of the t statistic (statistical significance) for the a, b, c, d, and e wave groups were 1.08292 (p=0.2855), 0.19607 (p=0.8456), 0.28955 (p=0.7737), 0.39467 (p=0.69467), and 0.50973 (p=0.6131), respectively. To identify waves of extreme values away from normality, the coefficient of kurtosis was obtained; the smallest value was obtained for the d wave (0.07335), and the largest value was obtained for the e wave (3.9456). The results suggested that the in-group waves did not significantly differ. The CLFACM played an important role in increasing the success rate of accurately detecting five waves from the APG signal.

Cite

CITATION STYLE

APA

Ahn*, J. M., & Kim, J. K. (2020). Wave Detection of Acceleration Plethysmogram Based on a Closed-Loop Feedback Mechanism. International Journal of Innovative Technology and Exploring Engineering, 9(7), 215–220. https://doi.org/10.35940/ijitee.g5180.059720

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free