Calculation of bone graft volume using 3D reconstruction system

5Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

Abstract

Objectives: To obtain bone "bioreplicas" for determining precisely the amount of biomaterial required for bone regeneration procedure. Study design: A case-control comparison with a total sample size of 20 cases, 10 control and 10 test samples. "Bioreplicas" were generated from helical CAT scans with 0.5 mm slices, without 3D reconstruction or image filters. Bone defects in premolar and molar areas were treated with titanium mesh and xenograft (MP3) combined with resorbable carriers. Time taken to carry out procedures with and without the use of "bioreplicas" (in minutes), discrepancies between the grafts performed with and without "bioreplicas" and bone defects (mm), and postoperative complications were registered. Results: No significant differences were recorded for measurements of width and length of bone defect between patient bone and the biological models. Conclusions: The use of "bioreplicas" obtained by rapid prototyping is effective in treatment planning. © Medicina Oral.

Cite

CITATION STYLE

APA

Calvo-Guirado, J. L., Maté-Sánchez, J. E., Delgado-Ruiz, R., & Ramírez-Fernández, M. P. (2011). Calculation of bone graft volume using 3D reconstruction system. Medicina Oral, Patologia Oral y Cirugia Bucal, 16(2). https://doi.org/10.4317/medoral.16.e260