Taking Advantage of Aerated‐Anoxic Operation in a Full‐Scale University of Cape Town Process

  • Park H
  • Whang L
  • Reusser S
  • et al.
17Citations
Citations of this article
21Readers
Mendeley users who have this article in their library.

Abstract

To evaluate the potential benefits or limitations of aerated‐anoxic operation in high‐rate biological nutrient removal processes, we conducted a full‐scale experiment in a University of Cape Town (UCT)‐type wastewater treatment plant by reducing oxygen supply and increasing flowrates within one treatment train so that aerated‐anoxic conditions (i.e., zones that receive oxygen but maintain dissolved oxygen concentrations below 0.5 mg/L) could be implemented in a section of the aerated zone. With this retrofitted configuration, total nitrogen removal increased from 54 to 65%, but was limited by the organic carbon available for denitrification. Furthermore, the significant reduction in dissolved oxygen concentrations in the aerated zone did not negatively affect enhanced biological phosphorus removal, demonstrating that the implementation of an aerated‐anoxic zone within a UCT‐type reactor can contribute to a reduction in operational costs and a slight improvement in total nitrogen removal, without compromising the extent of phosphorus removal.

References Powered by Scopus

Characterization of simultaneous nutrient removal in staged, closed-loop bioreactors

65Citations
N/AReaders
Get full text

Simultaneous nitrification-denitrification process in extended aeration plants: Pilot and real scale experiences

59Citations
N/AReaders
Get full text

Molecular analysis of ammonia-oxidizing bacterial populations in aerated-anoxic Orbal processes

57Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Ammonia-oxidizing microbial communities in reactors with efficient nitrification at low-dissolved oxygen

231Citations
N/AReaders
Get full text

Genome-enabled insights into the ecophysiology of the comammox bacterium "candidatus Nitrospira Nitrosa"

125Citations
N/AReaders
Get full text

Candidatus Accumulibacter phosphatis clades enriched under cyclic anaerobic and microaerobic conditions simultaneously use different electron acceptors

93Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Park, H., Whang, L., Reusser, S. R., & Noguera, D. R. (2006). Taking Advantage of Aerated‐Anoxic Operation in a Full‐Scale University of Cape Town Process. Water Environment Research, 78(6), 637–642. https://doi.org/10.2175/106143006x99786

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 5

50%

Professor / Associate Prof. 2

20%

Researcher 2

20%

Lecturer / Post doc 1

10%

Readers' Discipline

Tooltip

Engineering 5

42%

Environmental Science 5

42%

Chemical Engineering 1

8%

Computer Science 1

8%

Save time finding and organizing research with Mendeley