Abstract

Purpose: The multiple inert gas elimination technique (MIGET) is the reference method for evaluating pulmonary gas exchange. MIGET includes a complex experimental method and mathematical model, and has not been used routinely in clinical practice. A simpler mathematical model has been proposed, and was shown previously to fit inert gas data from oleic acid damage. This paper explores the capability of this simple model to describe more complex damage, and to calculate oxygenation data upon changing the inspired oxygen fraction (FIO 2), comparing these results with those obtained using MIGET. Methods: The comparison of oxygenation was done at different ventilator settings and at varying values of FIO2 in order to mimic the clinical conditions that occur in the intensive care unit. Results: The simple model describes inert gas data from heterogeneous lung damage within measurement noise. Model simulations performed using the MIGET and the simple model are comparable, the MIGET model simulating partial pressure of oxygen (PaO2) values on average 0.22 ± 0.59 kPa (±SD) higher than the simple model. Model simulations are also accurate with a difference between model simulated and measured values of PaO2 of 0.33 ± 1.48 kPa (±SD) for the MIGET model and 0.12 ± 1.33 kPa (±SD) for the simple model. This comparability and accuracy was similar over different ventilator settings. Conclusions: The simple model provides a description of lung damage and arterial oxygenation which is comparable to the MIGET, calculating PaO2 with acceptable accuracy and precision over the clinically relevant range of PaO2, and for different values of FIO2, positive end-expiratory pressure (PEEP), and inspiratory-to-expiratory ratio (I:E). © 2010 Copyright jointly held by Springer and ESICM.

Cite

CITATION STYLE

APA

Rees, S. E., Kjærgaard, S., Andreassen, S., & Hedenstierna, G. (2010). Reproduction of inert gas and oxygenation data: A comparison of the MIGET and a simple model of pulmonary gas exchange. Intensive Care Medicine, 36(12), 2117–2124. https://doi.org/10.1007/s00134-010-1981-7

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free