Comparison of corneal measurements in keratoconus using swept-source optical coherence tomography and combined Placido–Scheimpflug imaging

46Citations
Citations of this article
51Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: The aim of this study was to provide a comprehensive comparison of reliability of corneal topographic measurements in keratoconic eyes using swept-source optical coherence tomography (OCT) and a combined Placido–Scheimpflug imaging. Methods: A total of 30 eyes of 30 patients were included. The mean age was 31.2 ± 8.4 years. Two consecutive topographic measurements were obtained for one eye of each patient using swept-source OCT (CASIA) and combined Placido–Scheimpflug imaging (TMS-5). Test–retest reliability of CASIA and TMS-5 measurements including central corneal thickness (CCT) and thinnest corneal thickness (TCT), keratometry at steep (Ks) and flat (Kf) axes, average keratometry (Avg K), cylinder, and, best-fit spheres (BFS) of the anterior and posterior corneal surfaces were evaluated. Results: There was no systematic or scaling bias in any parameter in both devices. Systematic differences between CASIA and TMS-5 were found in posterior corneal Kf, Avg K and BFS, CCT and TCT (p ≤ 0.002); scaling differences between CASIA and TMS-5 were also found in CCT and TCT (p ≤ 0.002). Both machines illustrated adequate reliability. Intraclass correlation coefficients (ICC) ≥0.952 was recorded for all parameters measured with CASIA and ICC ≥ 0.914 was recorded for all parameters on TMS-5. CASIA showed significantly higher ICCs in CCT and TCT, and posterior corneal BFS (p < 0.001). Conclusions: This study showed significant differences in posterior corneal surface and corneal thickness measurements between swept-source OCT and combined Placido–Scheimpflug imaging in eyes with keratoconus. Swept-source OCT might be preferred over Placido–Scheimpflug imaging owing to better repeatability of measurements.

Cite

CITATION STYLE

APA

Chan, T. C. Y., Biswas, S., Yu, M., & Jhanji, V. (2017). Comparison of corneal measurements in keratoconus using swept-source optical coherence tomography and combined Placido–Scheimpflug imaging. Acta Ophthalmologica, 95(6), e486–e494. https://doi.org/10.1111/aos.13298

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free