A simple and portable paced step test for reproducible measurements of ventilation and oxygen consumption during exercise

9Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

Abstract

A single work rate paced step test is described. It was designed to allow the measurement of minute ventilation (V̇I) and oxygen consumption (V̇O2), under standardised conditions, during exercise in the clinic and lung function laboratory and in field work. The subjects and the operator found the test simple to perform. The values for ventilation at a given oxygen consumption were similar to those from more complex and stressful tests and had a high degree of reproducibility. The ergometer was a 12 inch (30 cm) step with hand rails. The subjects stepped up and down, once every four seconds in response to a buzzer for 10 minutes. V̇I and V̇O2 were measured with a small portable device. In 53 normal subjects of mean weight 69 (range 49-107) kg, mean V̇O2 measured during the last 5 minutes of the test was 0.89 (range 0.53-1.52) l/min. Weight and height were independent contributors to the oxygen cost of stepping. The ventilatory equivalent for oxygen (V̇IO2, which equals V̇I divided by V̇O2) increased with age, and was similar to normal values for ventilation at 1.0 l/min V̇O2 obtained by workers who used multiple work rate tests on more complex equipment. The within subject variation in V̇IO2, expressed as the coefficient of variation (cv) and calculated for each age decade, was 14%. This again compared very favourably with the cv for values of ventilation at 1.0 l/min V̇O2 from other studies. In 20 normal subjects daily testing showed significant falls in V̇O2 and V̇I over three days of 4% and 5.9% respectively; V̇IO2 fell by 2%. Testing over four consecutive weeks showed small significant differences between weeks but no clear trend; the within subject weekly variation accounted for less than 3.5% of the total variance for each of the variables. Testing at least four months apart showed a 3.3% fall in the oxygen cost of stepping. No significant diurnal effects on the exercise responses were found.

Cite

CITATION STYLE

APA

Jones, P. W., Wakefield, J. M., & Kontaki, E. (1987). A simple and portable paced step test for reproducible measurements of ventilation and oxygen consumption during exercise. Thorax, 42(2), 136–143. https://doi.org/10.1136/thx.42.2.136

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free