Abstract

This study aimed to analyze fracture strength in vitro by varying the axial height of the titanium insert and the labial height of the zirconia abutment in an internal connection implant to identify the titanium insert axial height with optimal mechanical stability. Sixty implants with an internal connection system were used. Two-piece zirconia abutments were used with the titanium inserts. Combinations of different titanium insert axial heights (mm) and zirconia abutment labial heights (mm) constituted five groups: Gr1 (1–3), Gr2 (3–3), Gr3 (3–5), Gr4 (5–3), and Gr5 (5–5). After thermocycling, a fracture load test was performed with a universal testing machine. The initial deformation load and the fracture load were measured and analyzed. The fractured surface and cross-section of the specimens were examined by scanning electron microscopy (SEM). The groups of titanium inserts with axial heights of 3 mm and 5 mm showed significantly greater initial deformation load and fracture load than the group with an axial height of 1 mm (p < 0.05), but there was no significant difference between the two groups with axial heights of 3 mm and 5 mm. The labial height of the zirconia abutment had no significant influence on the initial deformation load and fracture load. In some specimens in Gr4 and Gr5, cracking or bending of the titanium insert and abutment screw was observed on SEM. The axial height of the titanium insert should be designed to not be less than 3 mm to increase the fracture strength and promote the long-term stability of implants.

References Powered by Scopus

Zirconia as a ceramic biomaterial

2300Citations
N/AReaders
Get full text

Bacterial adhesion on commercially pure titanium and zirconium oxide disks: An in vivo human study

525Citations
N/AReaders
Get full text

Cement-retained versus screw-retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistry

417Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Effect of Titanium Base Abutment Height and Restorative Material on Torque Maintenance of Hybrid Abutment Restorations with Offset Implant Placement

0Citations
N/AReaders
Get full text

EFFECTS OF DENTAL TISSUE SUBSTRUCTURE AND SIZE ON FRACTURE STRENGTHS OF LITHIUM DISILICATE AND ZIRCONIA CERAMICS

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Song, S. R., Park, K. M., & Jung, B. Y. (2021). Fracture strength analysis of titanium insert-reinforced zirconia abutments according to the axial height of the titanium insert with an internal connection. PLoS ONE, 16(4 April). https://doi.org/10.1371/journal.pone.0249208

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 7

100%

Readers' Discipline

Tooltip

Medicine and Dentistry 8

89%

Arts and Humanities 1

11%

Save time finding and organizing research with Mendeley

Sign up for free