In vitro biomechanical comparison of headless compression versus cortex screws for fixation of simulated midbody proximal sesamoid bone fractures in horses

0Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

Abstract

A midbody fracture of a proximal sesamoid bone (PSB) is a severe injury, especially in racehorses. Screw fixation may be the only option for horses to return to athletic activity. In a cadaveric biomechanical study, fixation of simulated transverse midbody PSB fractures with a 4.5 mm headless compression screw (HCS) was compared to the fixation using a 4.5 mm cortex screw (CS) inserted in log fashion. The front limbs of 8 horses were prepared with a standardized midbody transverse osteotomy in each medial PSB. The left or the right limb of each pair was ran-domly assigned to the CS or HCS group. Fracture reduction and fixation was controlled by radiography. Markers were fixed proximal and distal to the osteotomy to document gap opening by an image correlation measurement. Cyclic compressive looding was applied with a hydraulic cylinder in an axial manner leading to tensile cyclic loading in the PSBs. After mechanical testing all limbs were radiographed to document the mode of failure. The mean cycles to total failure were 27,803 for the HCS group and 36,624 for the CS group, respectively. A mean of 14,444 cycles (HCS group) versus 27,464 cycles (CS group) wos recorded of a fracture gap opening of 10%. The mean value of initial stiffness was 300N/mm (HCS group) versus 590N/mm (CS group). On post-testing radiographs, failure by screw breakage was detected in 3/8 limbs of the HCS group and in 2/8 limbs of the CS group. Screw pullout and bone failure was noted in 5 limbs in each group. In one limb of the CS group, the medial suspensory branch was disrupted and the fracture fixation was intact. None of the differences between HCS and CS constructs reached statistical significance. However, the lower absolute numbers of cycles sustained before failure, at 10% gap opening and lower initial stiffness of HCS constructs as well as limitations of the study warrant further investigation before clinical use of the HCS for this indication can be recommended.

Cite

CITATION STYLE

APA

Bryner, M. F., Valet, S., Weisse, B., Furst, A. E., & Kummerle, J. M. (2019). In vitro biomechanical comparison of headless compression versus cortex screws for fixation of simulated midbody proximal sesamoid bone fractures in horses. Pferdeheilkunde, 35(5), 396–402. https://doi.org/10.21836/PEM20190501

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free