Optimization of Dual-Channel Near-Infrared Non-Invasive Glucose Level Measurement Sensors Based on Monte-Carlo Simulations

17Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Non-invasive glucose monitoring sensors are promising techniques in diabetes management. In particular, optical-based near-infrared glucose sensors are label-free, compact, user-friendly, and inexpensive. They require no daily calibration and can provide continuous glucose level monitoring. However, these sensors are still in the development stage since their accuracy is still not widely accepted by medical professionals. Here, we introduce an optimized dual-channel approach for this kind of sensor where four optodes for short and long channels are employed. The long channel signal that contains useful information about the glucose level can be utilized to calculate the glucose contents in the dermis layer of the skin while the short channel is utilized to measure the interference 'noise' signal originating from the epidermis layer. So, the latter can then be removed from the long channel signal. This work investigates the optimal source-detector separation (SDS) of both short and long channels for a wide range of wavelengths from 1200 nm to 1900 nm. Based on the sensitivity distributions of both dermis and epidermis layers and the signal-to-noise ratio, it is suggested that a 2 mm SDS distance with a wavelength of 1450 nm is a potential choice for the short channel. Moreover, 6 mm SDS at the wavelength of 1750 nm is the optimal choice for the long channel. This work may pave the way for further optimization of non-invasive near-infrared glucose sensors that will be widely adopted in the healthcare sector.

References Powered by Scopus

Electrochemical glucose biosensors

3090Citations
N/AReaders
Get full text

Monte carlo simulation of photon migration in 3D turbid media accelerated by graphics processing units

822Citations
N/AReaders
Get full text

Recent advances in electrochemical glucose biosensors: A review

733Citations
N/AReaders
Get full text

Cited by Powered by Scopus

A review of non-invasive optical systems for continuous blood glucose monitoring

67Citations
N/AReaders
Get full text

Review of Noninvasive Continuous Glucose Monitoring in Diabetics

25Citations
N/AReaders
Get full text

Is Raman the best strategy towards the development of non-invasive continuous glucose monitoring devices for diabetes management?

19Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Althobaiti, M., & Al-Naib, I. (2021). Optimization of Dual-Channel Near-Infrared Non-Invasive Glucose Level Measurement Sensors Based on Monte-Carlo Simulations. IEEE Photonics Journal, 13(3). https://doi.org/10.1109/JPHOT.2021.3079408

Readers over time

‘21‘22‘23‘24‘25036912

Readers' Seniority

Tooltip

Professor / Associate Prof. 4

44%

PhD / Post grad / Masters / Doc 4

44%

Researcher 1

11%

Readers' Discipline

Tooltip

Biochemistry, Genetics and Molecular Bi... 6

43%

Engineering 5

36%

Social Sciences 2

14%

Computer Science 1

7%

Save time finding and organizing research with Mendeley

Sign up for free
0