As the frequency of the three-phase power signal is instability and it contains multiple harmonics signal, the error can not be ignored when FFT algorithm applied to measure the phase directly. Although corrected by many correction methods such as ratio method, center of energy gravity method, etc. the precision of phase measurement is also severely influenced by harmonic signal. In order to solve these problems, the power phase measurement system is designed based on FPGA which embedded all-phase FFT algorithms. It realized the measurement of the phase with high accuracy, and the results indicate it almost immune to the harmonic and noise of power. © 2012 ICST Institute for Computer Science, Social Informatics and Telecommunications Engineering.

Author supplied keywords

Cite

CITATION STYLE

APA

Zhang, X., Zhang, Y., & Lu, X. (2012). Phase measurement of three-phase power based on FPGA. In Lecture Notes of the Institute for Computer Sciences, Social-Informatics and Telecommunications Engineering (Vol. 72 LNICST, pp. 170–179). https://doi.org/10.1007/978-3-642-29157-9_16