OBJECTIVE: To evaluate the presence of methicillin-resistant Staphylococcus aureus (MRSA) in areas close to patients in a General Intensive Care Unit. METHODS: This is a cross-sectional study, in which microbiological samples were collected from five surfaces (left / right bed siderails, bed crank, table, buttons on the infusion pump, and cotton gowns) from each of ten patient rooms, totaling 63 samples. To collect samples, the Petri FilmTM Staph Express Count System 3M TM was used to screen for methicillin resistance, with the Mueller-Hinton agar supplemented with 4% sodium chloride and 6 µg / ml of oxacillin. Descriptive analysis was conducted to determine the frequency (n) and percentage (%) of contamination of environmental surfaces. RESULTS: Of 48 samples positive for Staphylococcus aureus, 29 (60.4%) were resistant to methicillin. The incidence on the siderails and bed cranks, table, buttons on the infusion pumps and aprons were, respectively, 55.5%, 57.1%, 57.1%, 60.0% and 75.0%. CONCLUSION: The results suggest that the surfaces around the patient constitute a major threat, as they represent secondary reservoirs of MRSA.OBJETIVO: Evaluar la presencia de Staphylococcus aureus resistente a la meticilina (MRSA) en superficies cercanas a los pacientes internados en una Unidad de Cuidados Intensivos General. MÉTODOS: Se trata de un estudio transversal, en el cual se recolectaron muestras microbiológicas de cinco superficies (enrejados derecho/izquierdo, manivela de la cama, mesa, botones de la bomba de infusión y mandiles de algodón) de cada diez unidades de pacientes, totalizando 63 muestras. Para la recolección, se utilizaron placas Petri FilmTM Staph Express Count System 3M TM y para el triaje de resistencia a la meticilina, el agar Mueller-Hinton adicionado del 4% de cloruro de sodio y 6 µg/ml oxacilina. Se emplearon análisis descriptivos para determinar la frecuencia (n) y el porcentaje (%) de contaminación de las superficies ambientales. RESULTADOS: De las 48 muestras positivas para Staphylococcus aureus, 29 (60,4%) fueron resistentes a la meticilina. La incidencia en enrejados y manivelas de la cama, mesa, botones de la bomba de infusión y mandiles fue, respectivamente, 55,5%, 57,1%, 57,1%, 60,0% y 75,0%. CONCLUSIÓN: Los resultados sugieren que las superficies alrededor del paciente se constituye en una importante amenaza, pues representan reservorios secundarios de MRSA.OBJETIVO: Avaliar a presença de Staphylococcus aureus resistente à meticilina (MRSA) em superfícies próximas aos pacientes internados em uma Unidade de Terapia Intensiva Geral. MÉTODOS: Trata-se de um estudo transversal, no qual foram coletadas amostras microbiológicas de cinco superfícies (grades direita/esquerda, manivela da cama, mesa, botões da bomba de infusão e aventais de algodão) de cada dez unidades de pacientes, totalizando 63 amostras. Para a coleta, foram utilizadas placas Petri FilmTM Staph Express Count System 3M TM e para a triagem de resistência à meticilina, o ágar Mueller-Hinton adicionado de 4% de cloreto de sódio e 6 µg/ml oxacilina. Análises descritivas foram empregadas para determinar a frequência (n) e porcentagem (%) de contaminação das superfícies ambientais. RESULTADOS: Das 48 amostras positivas para Staphylococcus aureus, 29 (60,4%) foram resistentes à meticilina. A incidência em grades e manivelas da cama, mesa, botões da bomba de infusão e aventais foi, respectivamente, 55,5%, 57,1%, 57,1%, 60,0% e 75,0%. CONCLUSÃO: Os resultados sugerem que as superfícies ao redor do paciente constituí-se uma importante ameaça, visto que representam reservatórios secundários de MRSA.
CITATION STYLE
Ferreira, A. M., Andrade, D. de, Rigotti, M. A., & Almeida, M. T. G. de. (2011). Methicillin-resistant Staphylococcus aureus on surfaces of an Intensive Care Unit. Acta Paulista de Enfermagem, 24(4), 453–458. https://doi.org/10.1590/s0103-21002011000400002
Mendeley helps you to discover research relevant for your work.