Abstract

Purpose: The efficiency of radioembolization procedures could be greatly enhanced if results of the 99mTc-MAA pretreatment procedure were immediately available in the interventional suite, enabling 1-day procedures as a result of direct estimation of the hepatic radiation dose and lung shunt fraction. This would, however, require a relatively fast, but still quantitative, SPECT procedure, which might be achieved with acquisition protocols using nonuniform durations of the projection images. Methods: SPECT liver images of the 150-MBq 99mTc-MAA pretreatment procedure were simulated for eight different lesion locations and two different lesion sizes using the digital XCAT phantom for both single- and dual-head scanning geometries with respective total acquisition times of 1, 2, 5, 10, and 30 min. Three nonuniform projection-time acquisition protocols (“half-circle SPECT (HCS),” “nonuniform SPECT (NUS) I,” and “NUS II”) for fast quantitative SPECT of the liver were designed and compared with the standard uniform projection-time protocol. Images were evaluated in terms of contrast-to-noise ratio (CNR), activity recovery coefficient (ARC), tumor/non-tumor (T/N) activity concentration ratio, and lung shunt fraction (LSF) estimation. In addition, image quality was verified with a physical phantom experiment, reconstructed with both clinical and Monte Carlo-based reconstruction software. Results: Simulations showed no substantial change in image quality and dosimetry by usage of a nonuniform projection-time acquisition protocol. Upon shortening acquisition times, CNR dropped, but ARC, T/N ratio, and LSF estimates were stable across all simulated acquisition times. Results of the physical phantom were in agreement with those of the simulations. Conclusion: Both uniform and nonuniform projection-time acquisition liver SPECT protocols yield accurate dosimetric metrics for radioembolization treatment planning in the interventional suite within 10 min, without compromising image quality. Consequently, fast quantitative SPECT of the liver in the interventional suite is feasible.

References Powered by Scopus

Accelerated Image Reconstruction Using Ordered Subsets of Projection Data

3117Citations
N/AReaders
Get full text

4D XCAT phantom for multimodality imaging research

1060Citations
N/AReaders
Get full text

The sensitivity performance of the human eye on an absolute scale

669Citations
N/AReaders
Get full text

Cited by Powered by Scopus

EANM dosimetry committee series on standard operational procedures: a unified methodology for <sup>99m</sup>Tc-MAA pre- and <sup>90</sup>Y peri-therapy dosimetry in liver radioembolization with <sup>90</sup>Y microspheres

84Citations
N/AReaders
Get full text

Accelerated SPECT image reconstruction with FBP and an image enhancement convolutional neural network

34Citations
N/AReaders
Get full text

203/212pb theranostic radiopharmaceuticals for image-guided radionuclide therapy for cancer

31Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

van der Velden, S., Dietze, M. M. A., Viergever, M. A., & de Jong, H. W. A. M. (2019). Fast technetium-99m liver SPECT for evaluation of the pretreatment procedure for radioembolization dosimetry. Medical Physics, 46(1), 345–355. https://doi.org/10.1002/mp.13253

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

50%

Researcher 4

33%

Lecturer / Post doc 2

17%

Readers' Discipline

Tooltip

Medicine and Dentistry 4

40%

Nursing and Health Professions 2

20%

Physics and Astronomy 2

20%

Engineering 2

20%

Save time finding and organizing research with Mendeley

Sign up for free