Evaluation of k-wireless robotic and navigation assisted pedicle screw placement in adult degenerative spinal surgery: Learning curve and technical notes

26Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: K-wireless robotic pedicle screw instrumentation with navigation is a new technology with large potential. Barriers to adoption are added registration time with robotic-navigated system and reliable screw positioning. Understanding the learning curve and limitations is crucial for successful implementation. The purpose of this study was to describe a learning curve of k-wireless robotic assisted pedicle screw placement with navigation and compare to conventional techniques. Methods: A retrospective review of prospectively collected data of 65 consecutive adult patients underwent robotic-navigated posterior spinal fusion by a single spine surgeon. Registration, screw placement, and positioning times were recorded. All patients underwent intra-operative 3D fluoroscopy and screw trajectory was compared to pre-operative CT. Results: A total of 364 instrumented pedicles were planned robotically, 311 (85.4%) were placed robotically; 17 screws (4.7%) converted to k-wire, 21 (5.8%) converted to freehand, and 15 (4.1%) planned freehand. Of the 311 robotically placed pedicle screws, three dimensional fluoroscopic imaging showed 291 (93.5%) to be GRS Grade A in the axial plane (fully contained within the pedicle) and 281 (90.4%) were GRS Grade A in the sagittal plane. All breached screw deviations from plan were identified on 3D fluoroscopy during surgery and repositioned and confirmed by additional 3d fluoroscopy scan. Reasons for conversion included morphology of starting point (n=18), soft tissue pressure (n=9), hypoplastic pedicles (n=6), obstructive reference pin placement (n=2), and robotic arm issues (n=1). Seventeen (5.5%) critical breaches (≥2−4 mm) were recorded in 11 patients, 9 (2.9%) critical breaches were due to soft tissue pressure causing skive. Two patients experienced 6 (1.9%) critical breaches from hypoplastic pedicles, and 3 (0.9%) unplanned lateral breaches were found in another patient. One patient (0.3%) experienced skive due to morphology and spinal instability from isthmic spondylolisthesis. Imaging showed 143 screws placed medially to plan (1.2±0.9 mm), 170 lateral (1.2±1.1 mm), 193 screws caudal (1.0±0.6 mm) and 117 cranial (0.6±0.5 mm). No adverse clinical sequelae occurred from implantation of any screw. Conclusions: The learning curve showed improvement in screw times for the first several cases. Understanding the learning curve and situations where the robotic technique may be suboptimal can help guide the surgeon safe and effectively for adoption, as well as further refine these technologies.

References Powered by Scopus

Accuracy of pedicle screw placement: A systematic review of prospective in vivo studies comparing free hand,fluoroscopy guidance and navigation techniques

531Citations
N/AReaders
Get full text

Clinical acceptance and accuracy assessment of spinal implants guided with spineassist surgical robot: Retrospective study

332Citations
N/AReaders
Get full text

Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement

330Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Learning curves in robot-assisted spine surgery: a systematic review and proposal of application to residency curricula

42Citations
N/AReaders
Get full text

Robotics in spine surgery: systematic review of literature

39Citations
N/AReaders
Get full text

Robotic-navigated assistance in spine surgery A SINGLE-SURGEON EXPERIENCE WITH 1,001 PEDICLE SCREWS

20Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Avrumova, F., Morse, K. W., Heath, M., Widmann, R. F., & Lebl, D. R. (2021). Evaluation of k-wireless robotic and navigation assisted pedicle screw placement in adult degenerative spinal surgery: Learning curve and technical notes. Journal of Spine Surgery, 7(2), 141–154. https://doi.org/10.21037/jss-20-687

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 5

71%

Researcher 2

29%

Readers' Discipline

Tooltip

Medicine and Dentistry 6

67%

Pharmacology, Toxicology and Pharmaceut... 1

11%

Computer Science 1

11%

Nursing and Health Professions 1

11%

Article Metrics

Tooltip
Mentions
News Mentions: 3

Save time finding and organizing research with Mendeley

Sign up for free