Usefulness and limitations of thallium-201 myocardial scintigraphy in delineating location and size of prior myocardial infarction

48Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

In order to evaluate the usefulness of thallium-201 (201Tl) myocardial scintigraphy in delineating the location and size of prior myocardial infarction, 32 patients were evaluated at a mean of 7 ± 2 months after infarction with a 12-lead ECG, resting 201Tl myocardial scintigram, biplane left ventriculogram and coronary angiograms. From the left ventriculogram, asynergy was quantified as percent abnormally contracting segment (% ACS), the percent of end-diastolic circumference which was either akinetic or dyskinetic. Using a computerized planimetry system, we expressed 201Tl perfusion defects as a percentage of total potential thallium uptake. Of 21 patients with ECG evidence of prior transmural infarction, a 201Tl defect was present in 20 (95%), and angiographic asynergy was present in all 21 (100%). The site of prior infarction by ECG agreed with the 201Tl defect location in 24 of 32 patients (75%) and with site of angiographic asynergy in 23 of 32 patients (72%). Scintigraphic defects were present in only four of 10 patients (40%) with ACS ≤ 6%, but scintigraphic defects were found in 20 of 22 patients (91%) with ACS > 6% (p < 0.01). Thallium defect size correlated marginally with angiographic left ventricular ejection fraction (r = - 0.60) but correlated closely with angiographic % ACS (r = 0.80). Thallium defect size was similar among patients with one-, two, or three-vessel coronary artery disease (≥ 70% stenosis), but thallium defect size was larger in patients with electrocardiographic evidence of transmural infarction (p < 0.01) or pulmonary capillary wedge pressure > 12 mm Hg (p < 0.001). Thus, resting 201Tl myocardial scintigraphy is useful in localizing and quantifying the extent of prior myocardial infarction, but is insensitive to small infarcts (ACS < 6%).

Cite

CITATION STYLE

APA

Niess, G. S., Logic, J. R., Russell, R. O., Rackley, C. E., & Rogers, W. J. (1979). Usefulness and limitations of thallium-201 myocardial scintigraphy in delineating location and size of prior myocardial infarction. Circulation, 59(5), 1010–1019. https://doi.org/10.1161/01.CIR.59.5.1010

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free