Transcatheter closure of high pulmonary artery pressure persistent ductus arteriosus with the Amplatzer muscular ventricular septal defect occluder

66Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

Abstract

Background: The design of devices currently used for closure of persistent ductus arteriosus (PDA) with high pulmonary artery pressure is not ideal and there is a risk of embolisation into the aorta. Objective: To investigate the use of the Amplatzer muscular ventricular septal defect occluder (AMVSDO) for treatment of PDA with high pulmonary artery pressure. Patients and design: Seven patients, aged 5-12 years, with large PDAs and systemic or near systemic pulmonary artery pressure underwent attempted transcatheter closure using the AMVSDO. The device consists of two low profile disks made of a nitinol wire mesh with a 7 mm connecting waist. Balloon occlusion of the duct was performed before closure from the venous side, and prosthesis size was chosen according to the measured diameter of the occluding balloon. A 7 French sheath was used to deliver the device. All patients underwent a complete haemodynamic and angiographic study one year after occlusion. Results: The mean (SD) angiographic PDA diameter was 9.8 (1.7) mm (range 7-13 mm) and the mean AMVSDO diameter was 11.4 (1.8) mm (range 9-16 mm). Qp/Qs ranged from 1.9-2.2 (mean 2.0 (0.1)). Successful device delivery and complete closure occurred in all patients (100% occlusion rate, 95% confidence interval 59.04% to 100.00%). Mean systolic pulmonary artery pressures were as follows: before balloon occlusion, 106 (13) mm Hg; during occlusion, 61 (6) mm Hg; immediately after the procedure, 57 (5) mm Hg; and at the one year follow up catheterisation, 37 (10) mm Hg. Fluoroscopy time was 10.4 (4.3) min (range 7-18 min). No complications occurred. Conclusions: AMVSDO is an important adjunct for closure of large PDAs associated with high pulmonary artery pressure. Further studies are required to document its efficacy, safety, and long term results in a larger number of patients.

References Powered by Scopus

Angiographic classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion

580Citations
N/AReaders
Get full text

Nonsurgical closure of patent ductus arteriosus: Clinical application of the Rashkind PDA Occluder System

395Citations
N/AReaders
Get full text

Catheter closure of moderate- to large-sized patent ductus arteriosus using the new Amplatzer duct occluder: Immediate and short-term results

345Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Indications for cardiac catheterization and intervention in pediatric cardiac disease: A scientific statement from the American Heart Association

687Citations
N/AReaders
Get full text

Transcatheter closure of patent ductus arteriosus with severe pulmonary arterial hypertension in adults

88Citations
N/AReaders
Get full text

Preoperative pulmonary hemodynamics and assessment of operability: Is there a pulmonary vascular resistance that precludes cardiac operation?

71Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Thanopoulos, B. D., Tsaousis, G. S., Djukic, M., Al Hakim, F., Eleftherakis, N. G., & Simeunovic, S. D. (2002). Transcatheter closure of high pulmonary artery pressure persistent ductus arteriosus with the Amplatzer muscular ventricular septal defect occluder. Heart, 87(3), 260–263. https://doi.org/10.1136/heart.87.3.260

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 3

43%

Professor / Associate Prof. 2

29%

Lecturer / Post doc 2

29%

Readers' Discipline

Tooltip

Medicine and Dentistry 9

82%

Agricultural and Biological Sciences 1

9%

Engineering 1

9%

Save time finding and organizing research with Mendeley

Sign up for free