Effect of a ferrule and increased clinical crown length on the in vitro fracture resistance of premolars restored using two dowel-and-core systems

22Citations
Citations of this article
86Readers
Mendeley users who have this article in their library.

Abstract

This study investigated the effect of a crown-lengthening ferrule on the fracture resistance of endodontically-treated teeth restored with two dowel-core systems. Thirty-two extracted mandibular first premolars were sectioned perpendicular to the long axis at a point 1.0 mm occlusal to the buccal cementoenamel junction. Following endodontic treatment, the teeth were randomly assigned to four groups: cast Ni-Cr alloy dowel-core with no ferrule (Group Al), cast Ni-Cr alloy dowel-core with 2.0 mm ferrule (Group A2), prefabricated carbon fiber-reinforced dowel-resin core with no ferrule (Group Bl) and carbon fiber-reinforced dowel-resin core with 2.0 mm ferrule (Group B2). Each specimen was embedded in a self-cured acrylic resin block from 2.0 mm apical to the margins of a cast Ni-Cr alloy crown, then loaded at 150° from the long axis in a universal testing machine at a crosshead speed of 1.0 mm/minute until fracture. The data were recorded and analyzed using ANOVA and Fisher's exact tests, with α=0.05. Mean failure loads (kN) for the A1, A2, B1 and B2 Groups were: 1.46 (S.D. 0.45), 1.07 (0.21), 1.13 (0.30) and 1.02 (0.27). The teeth restored with cast Ni-Cr dowel-cores and 2.0 mm ferrules demonstrated significantly lower fracture strengths, pa0.04. There were significant differences in the root fracture patterns between the two dowel systems, with the carbon fiber-reinforced dowelresin core system, being the less severe p<0.05. Crown lengthening with a 2.0 mm apical extended ferrule resulted in reduced fracture strengths for endodontically-treated teeth restored using two dowel-core systems and cast metal crowns. The carbon fiber-reinforced dowel-resin core system reduced the severity of the root fractures. © Operative Dentistry.

Cite

CITATION STYLE

APA

Meng, Q. F., Chen, Y. M., Guang, H. B., Yip, K. H. K., & Smales, R. J. (2007). Effect of a ferrule and increased clinical crown length on the in vitro fracture resistance of premolars restored using two dowel-and-core systems. Operative Dentistry, 32(6), 595–601. https://doi.org/10.2341/06-169

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free