Multi-MGy Radiation Hard CMOS Image Sensor: Design, Characterization and X/Gamma Rays Total Ionizing Dose Tests

23Citations
Citations of this article
29Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

A Radiation Hard CMOS Active Pixel Image Sensor has been designed, manufactured and exposed to X and {60}{rm Co} gamma-ray sources up to several MGy of Total Ionizing Dose (TID). It is demonstrated that a Radiation-Hardened-By-Design (RHBD) CMOS Image Sensor (CIS) can still provide useful images after 10hbox{MGy}({rm SiO}-2) (i.e. 1 Grad). This paper also presents the first detailed characterizations of CIS opto-electrical performances (i.e. dark current, quantum efficiency, gain, noise, transfer functions, etc.) in the MGy range. These results show that it is possible to design a CIS with good performances even after having absorbed several MGy. Four different RHBD photodiode designs are compared: a standard photodiode design, two well known RHBD layouts and a proposed improvement of the gated photodiode design. The proposed layout exhibits the best performances over the entire studied TID range and further optimizations are discussed. Several original MGy radiation effects are presented and discussed at the device and circuit levels and mitigation techniques are proposed to improve further the radiation hardness of future Rad-Hard CIS developments for extreme TID applications (e.g. for nuclear power plant monitoring/dismantling, experimental reactors (e.g. ITER) or next generation particle physics experiments (e.g. CERN)).

References Powered by Scopus

CMOS image sensors: electronic camera-on-a-chip

1073Citations
N/AReaders
Get full text

Radiation-induced edge effects in deep submicron CMOS transistors

380Citations
N/AReaders
Get full text

A review of the pinned photodiode for CCD and CMOS image sensors

371Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Total Ionizing Dose Effects on a Radiation-Hardened CMOS Image Sensor Demonstrator for ITER Remote Handling

31Citations
N/AReaders
Get full text

Effect of gamma-ray irradiation on microstructure and mechanical property of Sn63Pb37 solder joints

28Citations
N/AReaders
Get full text

Radiation Hardening of Digital Color CMOS Camera-on-a-Chip Building Blocks for Multi-MGy Total Ionizing Dose Environments

26Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Goiffon, V., Corbiere, F., Rolando, S., Estribeau, M., Magnan, P., Avon, B., … Marcandella, C. (2015). Multi-MGy Radiation Hard CMOS Image Sensor: Design, Characterization and X/Gamma Rays Total Ionizing Dose Tests. In IEEE Transactions on Nuclear Science (Vol. 62, pp. 2956–2964). Institute of Electrical and Electronics Engineers Inc. https://doi.org/10.1109/TNS.2015.2490479

Readers over time

‘16‘17‘18‘19‘20‘21‘22‘2302468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 10

56%

Researcher 6

33%

Professor / Associate Prof. 1

6%

Lecturer / Post doc 1

6%

Readers' Discipline

Tooltip

Engineering 17

81%

Physics and Astronomy 3

14%

Design 1

5%

Save time finding and organizing research with Mendeley

Sign up for free
0