Criterion validation testing of clinical metrology instruments for measuring degenerative joint disease associated mobility impairment in cats

70Citations
Citations of this article
115Readers
Mendeley users who have this article in their library.

Abstract

Introduction: Degenerative joint disease and associated pain are common in cats, particularly in older cats. There is a need for treatment options, however evaluation of putative therapies is limited by a lack of suitable, validated outcome measures that can be used in the target population of client owned cats. The objectives of this study were to evaluate low-dose daily meloxicam for the treatment of pain associated with degenerative joint disease in cats, and further validate two clinical metrology instruments, the Feline Musculoskeletal Pain Index (FMPI) and the Client Specific Outcome Measures (CSOM). Methods: Sixty-six client owned cats with degenerative joint disease and owner-reported impairments in mobility were screened and enrolled into a double-masked, placebo-controlled, randomized clinical trial. Following a run-in baseline period, cats were given either placebo or meloxicam for 21 days, then in a masked washout, cats were all given placebo for 21 days. Subsequently, cats were given the opposite treatment, placebo or meloxicam, for 21 days. Cats wore activity monitors throughout the study, owners completed clinical metrology instruments following each period. Results: Activity counts were increased in cats during treatment with daily meloxicam (p<0.0001) compared to baseline. The FMPI results and activity count data offer concurrent validation for the FMPI, though the relationship between baseline activity counts and FMPI scores at baseline was poor (R 2 =0.034). The CSOM did not show responsiveness for improvement in this study, and the relationship between baseline activity counts and CSOM scores at baseline was similarly poor (R 2 =0.042). Conclusions: Refinements to the FMPI, including abbreviation of the instrument and scoring as percent of possible score are recommended. This study offered further validation of the FMPI as a clinical metrology instrument for use in detecting therapeutic efficacy in cats with degenerative joint disease. Copyright:

References Powered by Scopus

Prevalence and classification of chronic kidney disease in cats randomly selected from four age groups and in cats recruited for degenerative joint disease studies

175Citations
N/AReaders
Get full text

Cross-Sectional Study of the Prevalence of Radiographic Degenerative Joint Disease in Domesticated Cats

156Citations
N/AReaders
Get full text

Caregiver placebo effect for dogs with lameness from osteoarthritis

156Citations
N/AReaders
Get full text

Cited by Powered by Scopus

2022 AAHA Pain Management Guidelines for Dogs and Cats

92Citations
N/AReaders
Get full text

Veterinary Epidemiology: Fourth Edition

86Citations
N/AReaders
Get full text

Anti-nerve growth factor monoclonal antibodies for the control of pain in dogs and cats

78Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Gruen, M. E., Griffith, E. H., Thomson, A. E., Simpson, W., & Lascelles, B. D. X. (2015). Criterion validation testing of clinical metrology instruments for measuring degenerative joint disease associated mobility impairment in cats. PLoS ONE, 10(7). https://doi.org/10.1371/journal.pone.0131839

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 36

59%

Researcher 14

23%

Professor / Associate Prof. 8

13%

Lecturer / Post doc 3

5%

Readers' Discipline

Tooltip

Veterinary Science and Veterinary Medic... 45

69%

Medicine and Dentistry 11

17%

Agricultural and Biological Sciences 6

9%

Biochemistry, Genetics and Molecular Bi... 3

5%

Save time finding and organizing research with Mendeley

Sign up for free