Does a low volume ultrasound-guided technique reduce common complications of interscalene brachial plexus block (ISBPB)?

  • Riazi S
  • Awad I
  • Carmichael N
  • et al.
N/ACitations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction: ISBPB is one of the most effective and reliable nerve blocks for shoulder surgery(1). However, a one hundred percent incidence of phrenic nerve palsy(2) limits its useful application in patients with limited pulmonary reserve. In this study we examined the incidence of phrenic nerve palsy and diaphragmatic function with an ultrasound-guided low volume (5ml) ISBPB compared to a standard technique. METHODS: In this double-blind, randomized controlled trial after REB approval and informed consent forty patients, undergoing right-sided shoulder surgery, were enrolled, and randomized into two groups, receiving an ultrasound-guided posterior approach ISBPB of either 5ml or 20 ml ropivacaine 0.5%. General anesthesia was standardized. Both groups were assessed for respiratory function by visualizing diaphragmatic movement sonographically, and by measuring lung volumes using spirometry before and after receiving ISBPB, and also after surgery. As part of the respiratory function assessment, change in room air Oxygen saturation was also measured. The primary outcome was diaphragmatic function 30 minutes following ISBPB insertion. Pain scores at 12, and 24 hours, sleep quality, and total morphine equivalent consumption were additional secondary outcomes. Statistical comparison of continuous variables was analyzed using ANOVA and students t-test. Non-continuous variables were analyzed using chi-squared test. Significance is considered as p values lower than 0.05. RESULTS: The incidence of diaphragmatic paralysis was significantly lower in the low-volume group at 30 minutes after the block (45% vs. 100%, p=0.001), and 60 minutes after the surgery (33% vs. 90%, p=0.001). Reduction in FEV1 (-0.60 vs. -1.23, p=0.001), FVC (-0.70 vs. -1.59, p=0.001), and PEF (-0.83 vs. -2.50, p=0.001) at 30 minutes after the block were also significantly less in the low-volume group. In addition, there was a significantly greater drop in Oxygen saturation in the standard-volume group (-5.85 vs. -1.50, p=0.004). Pain scores in low, and high-volume groups measured at 12 (mean: 3.26 vs. 2.84, p=0.428), and 24 hours (mean: 4.89 vs. 5.84, p=0.226) after the block, as well as sleep quality, and total morphine consumption (mean: 13.95 vs. 13.89, p=0.993) were statistically similar. There were three cases of Horner's syndrome, and three cases of hoarseness that all occurred in standard volume group. Additionally, there was a case of persistent hiccups in a patient who received standard volume ISBPB that lasted 3 days.Discussion: Our results indicate that the use of low volume (5 ml) of ropivacaine 0.5% for ISBPB, is associated with lower incidence of phrenic nerve palsy, better preservation of diaphragmatic function, and overall fewer complications with no change in postoperative analgesia compared to standard-volume.

Cite

CITATION STYLE

APA

Riazi, S., Awad, I., Carmichael, N., Holtby, R., & McCartney, C. (2008). Does a low volume ultrasound-guided technique reduce common complications of interscalene brachial plexus block (ISBPB)? Canadian Journal of Anesthesia/Journal Canadien d’anesthésie, 55(S1), 4521251–4521252. https://doi.org/10.1007/bf03016381

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free