Investigation of brix refractometry for estimating bovine colostrum immunoglobulin G concentration

6Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

Abstract

Many dairy operations uses a Brix refractometer to assess the quality of first-milking colostrum. This study investigated whether a digital Brix refractometer could be used in a model to predict colostrum IgG concentration and whether more than one %Brix threshold could be used for different colostrum IgG concentrations. Colostrum from 182 animals was tested using a digital Brix refractometer and by single radial immunodiffusion. Statistical analysis, using simple linear regression to relate %Brix results with corresponding colostral IgG concentration, and receiver operating characteristic (ROC) analysis were used to identify %Brix cutoffs that had no false positive results. Colostral IgG concentrations from digital Brix refractometry had a R2 value of 0.818 and a S-value of 21.7 g/L. The large S-value shows that a digital Brix refractometer should not be used in a model to predict colostrum IgG concentration. However, %Brix scores of 19.0, 22.0, 25.0 and 30.0 percent can be used to estimate minimum colostral IgG concentrations of 25, 50, 75 and 100 g/L. These four cutoffs can be used to strategically feed smaller volumes of colostrum to newborn calves. Smaller volumes may reduce unwanted side effects and shorten the time interval in which calves refuse to nurse, while still delivering an adequate mass of IgG to have successful transfer of passive immunity.

References Powered by Scopus

Stratified randomization for clinical trials

458Citations
N/AReaders
Get full text

Colostrum Management for Dairy Calves

330Citations
N/AReaders
Get full text

Managing the production, storage, and delivery of colostrum

323Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Randomized prospective study exploring health and growth outcomes for 5 days of extended transition milk feeding in pre-weaned Scottish replacement dairy heifers

0Citations
N/AReaders
Get full text

The diagnostic accuracy of the Brix refractometer in determining mare colostrum with high and low immunoglobulin G concentrations

0Citations
N/AReaders
Get full text

Metabolic profile of prepartum dairy cows and its influence on the immediate postpartum period, colostrum quality and passive immunity transference

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Sockett, D., Breuer, R. M., Smith, L. W., Keuler, N. S., & Earleywine, T. (2023). Investigation of brix refractometry for estimating bovine colostrum immunoglobulin G concentration. Frontiers in Veterinary Science, 10. https://doi.org/10.3389/fvets.2023.1240227

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

67%

Researcher 1

33%

Readers' Discipline

Tooltip

Agricultural and Biological Sciences 2

67%

Computer Science 1

33%

Article Metrics

Tooltip
Mentions
News Mentions: 1
Social Media
Shares, Likes & Comments: 1

Save time finding and organizing research with Mendeley

Sign up for free