Efecto in vitro de la adición de resinas de intercambio iónico sobre la biodisponibilidad de electrolitos en fórmulas de nutrición enteral artificial

  • Martí Bonmati E
  • Tomas Bondia F
  • Milara J
  • et al.
N/ACitations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

OBJETIVO Conocer la concentración iónica libre in vitro en tres fórmulas de nutrición enteral artificial estándar, tras la adición de resinas de intercambio iónico. MÉTODO Se seleccionaron tres tipos de NEA estándar: Osmolite HN®, Nutrison Standard® e Issosource Standard®. Las resinas de intercambio iónico empleadas fueron: poliestireno sulfonato sódico y poliestireno sulfonato cálcico. En un vaso de precipitados se mezclaron 100 ml de la NEA con 1,5 g o 3 g de las resinas de intercambio iónico durante 48 h a 37 °C. Posteriormente se precipitaron las muestras y el sobrenadante obtenido se utilizó para determinar las concentraciones de los iones calcio, magnesio, sodio y potasio. RESULTADOS La adición de poliestireno sulfonato sódico a las diferentes nutriciones enterales redujo las concentraciones de los iones potasio, calcio y magnesio en un 70,9, 78,2, y 77,6% en el caso de Osmolite HN®, en un 72,3, 69,2 y 63,5% en el caso de Nutrison Standard®, y en un 78,3, 80,5 y 74,5% en el caso de Issosource Standard®. Por el contrario la adición de poliestireno sulfonato cálcico redujo las concentraciones de potasio y magnesio en un 50,5 y un 55,5% en el caso de Osmolite HN®, un 49,8 y un 43% en el caso de Nutrison Standard® y en un 42,6 y un 37,7% en el caso de Issosource Standard®. CONCLUSIONES La adición de resinas de intercambio iónico a distintas nutriciones enterales permite reducir el contenido iónico libre in vitro de éstas. OBJECTIVE To determine in vitro free ion concentration in three standard artificial enteral feeding formulas following the addition of ion exchange resins. METHOD Three standard types of AEF were chosen: Osmolite HN®, Nutrison Standard® and Isosource Standard®. The ion exchange resins used were: Sodium Polystyrene Sulfonate and Calcium Polystyrene Sulfonate. 100ml of AEF were mixed in a beaker with 1.5g or 3g of ion exchange resins for 48 hours at 37°C. Subsequently, the samples were precipitated and the supernatant obtained was used for determining the concentrations of calcium, magnesium, sodium and potassium ions. RESULTS The addition of Sodium Polystyrene Sulfonate to different types of enteral feeding formulas reduced the concentrations of potassium, calcium and magnesium ions by 70%. 78.2%, and 77.6% in the case of Osmolite HN®; by 72.3%, 69.2% and 63.5% in the case of Nutrison Standard®, and by 78.3%, 80.5% and 74.5% in the case of Isosource Standard®. In contrast, the addition of Calcium Polystyrene Sulfonate reduced the concentration of potassium and magnesium by 50.5% and 55.5% in the case of Osmolite HN®; by 49.8% and 43% in the case of Nutrison Standard® and by 42.6% and 37.7% in the case of Isosource Standard®. CONCLUSIONS The addition of ion exchange resins to different types of enteral feeding formulas, allows the in vitro free ion content of these to be reduced.

Cite

CITATION STYLE

APA

Martí Bonmati, E., Tomas Bondia, F., Milara, J., & Cortijo, J. (2008). Efecto in vitro de la adición de resinas de intercambio iónico sobre la biodisponibilidad de electrolitos en fórmulas de nutrición enteral artificial. Farmacia Hospitalaria, 32(2), 91–95. https://doi.org/10.1016/s1130-6343(08)72820-4

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free