Alteration of hemodynamics in aneurysm models by stenting: Influence of stent porosity

  • Lieber B
  • Stancampiano A
  • Wakhloo A
  • 62

    Readers

    Mendeley users who have this article in their library.
  • 199

    Citations

    Citations of this article.

Abstract

Recent developments in minimally invasive ap- proach to cerebrovascular diseases include the placement of stents in arteries for treatment of aneurysms. Preliminary clinical observations and experimental studies have shown that intravas- cular stents traversing the orifice may lead to thrombosis and subsequent occlusion of the aneurysm. The alterations in vessel local hemodynamics due to the introduction of a stent are not yet well understood. We investigated changes in local hemodynam- ics resulting from stent implantation. Pulsatile flow patterns in an experimental flow apparatus were visualized using laser-induced fluorescence of rhodamine dye. The test cells were constructed in a rectangular shape to facilitate an undisturbed longitudinal view of flow patterns in parent vessel and aneurysm models with and without porous stents. Woven nitinol stents of various porosities (76%, 80%, 82%, and 85%) were investigated. The selected fluid dynamic similarity parameters (Reynolds and Womersley num- bers) represented conditions usually found in high-flow, larger arteries in humans (such as the carotid artery) and low-flow, smaller arteries (such as the vertebral artery). The mean Reyn- olds number for the larger arteries was 180, with maximum/ minimum values of 490/-30 and the Womersley number was 5.3. The mean Reynolds number for the smaller arteries was 90, with maximum/minimum values of 230/2, and the Womersley num- ber was 2.7. For the larger arteries modeled, placement of a stent of the lowest porosity across the aneurysm orifice resulted in reduction of aneurysmal vortex speed and decreased interaction with parent vessel flow. For smaller arteries, a stent of the same porosity led to a substantial reduction of parent vessel/ aneurysmal flow interaction and the appearance of a nonrecircu- lating crescent of fluid rich in rhodamine dye in the aneurysm dome. Our results can help explain in vivo thrombus formation within an aneurysm after placement of a stent that is compatible with

Author-supplied keywords

  • Aneurysm
  • Cerebrovascular
  • Hemodynamics
  • Intravascular stent
  • Laser-induced fluorescence

Get free article suggestions today

Mendeley saves you time finding and organizing research

Sign up here
Already have an account ?Sign in

Find this document

Authors

  • Baruch B. Lieber

  • Alfred P. Stancampiano

  • Ajay K. Wakhloo