Comparison of two different methods for physiologic dead space measurements in ventilated dogs in a clinical setting

10Citations
Citations of this article
46Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objective: To compare physiologic dead space (VD) and physiologic dead space to tidal volume (VT) ratio (VD/VT) obtained by an automated single breath test for carbon dioxide (CO2) (method SBT) and a manual calculation (method MC) in ventilated healthy dogs. Study design: Prospective clinical study. Animals: Twenty client-owned dogs, ASA I and II undergoing anaesthesia for clinical purposes. Methods: Following pre-medication, induction of anaesthesia, and intubation of the trachea, intermittent positive pressure ventilation was commenced. Mixed expired CO2 partial pressure (PĒCO2) was measured by two methods: method MC by analysis, using an infrared capnograph, of the expired gas collected in a mixing box and method SBT which calculated it automatically by a device consisting of a mainstream capnograph and a pneumotachograph. At four time points arterial partial pressure of CO2 (PaCO2) was measured. Physiologic dead space variables (VD and VD/VT) were calculated manually (method MC) or automatically (method SBT) using the Bohr-Enghoff equation.Method MC and SBT were compared using Bland-Altman plots and linear regression. Intra-class correlation coefficient (ICC) was used to measure consistency of each method. Results: Four measurement pairs were obtained in all 20 dogs for method SBT and MC. The bias was -1.15 mmHg, 7.97 mL and 0.02 for PĒCO2, VD and VD/VT, respectively. Linear regression analysis revealed a correlation coefficient (r2) of 0.79, 0.94, and 0.83 for PĒCO2, VD and VD/VT, respectively. The ICC revealed an excellent consistency for both methods. Conclusions: The single breath test (SBT) can be used for clinical evaluation of VD and VD/VT in anaesthetized ventilated dogs. Clinical relevance: Through measuring VD and VD/VT important information about lung ventilation can be obtained and the SBT is an easy method to use for this purpose. © 2010 The Authors. Journal compilation © 2010 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesiologists.

Cite

CITATION STYLE

APA

Mosing, M., Staub, L., & Moens, Y. (2010). Comparison of two different methods for physiologic dead space measurements in ventilated dogs in a clinical setting. Veterinary Anaesthesia and Analgesia, 37(5), 393–400. https://doi.org/10.1111/j.1467-2995.2010.00548.x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free