Integrated lateral flow test strip with electrochemical sensor for quantification of phosphorylated cholinesterase: Biomarker of exposure to organophosphorus agents

125Citations
Citations of this article
141Readers
Mendeley users who have this article in their library.
Get full text

Abstract

An integrated lateral flow test strip with an electrochemical sensor (LFTSES) device with rapid, selective, and sensitive response for quantification of exposure to organophosphorus (OP) pesticides and nerve agents has been developed. The principle of this approach is based on parallel measurements of postexposure and baseline acetylcholinesterase (AChE) enzyme activity, where reactivation of the phosphorylated AChE is exploited to enable measurement of the total amount of AChE (including inhibited and active) which is used as a baseline for calculation of AChE inhibition. Quantitative measurement of phosphorylated adduct (OP-AChE) was realized by subtracting the active AChE from the total amount of AChE. The proposed LFTSES device integrates immunochromatographic test strip technology with electrochemical measurement using a disposable screen printed electrode which is located under the test zone. It shows a linear response between AChE enzyme activity and enzyme concentration from 0.05 to 10 nM, with a detection limit of 0.02 nM. On the basis of this reactivation approach, the LFTSES device has been successfully applied for in vitro red blood cells inhibition studies using chlorpyrifos oxon as a model OP agent. This approach not only eliminates the difficulty in screening of low-dose OP exposure because of individual variation of normal AChE values but also avoids the problem in overlapping substrate specificity with cholinesterases and avoids potential interference from other electroactive species in biological samples. It is baseline free and thus provides a rapid, sensitive, selective, and inexpensive tool for in-field and point-of-care assessment of exposures to OP pesticides and nerve agents. © 2011 American Chemical Society.

Cite

CITATION STYLE

APA

Du, D., Wang, J., Wang, L., Lu, D., & Lin, Y. (2012). Integrated lateral flow test strip with electrochemical sensor for quantification of phosphorylated cholinesterase: Biomarker of exposure to organophosphorus agents. Analytical Chemistry, 84(3), 1380–1385. https://doi.org/10.1021/ac202391w

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free