Long-term intra-fractional motion of the prostate using hydrogel spacer during Cyberknife® treatment for prostate cancer - a case report

9Citations
Citations of this article
49Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: There is a trend towards hypofractionated stereotactic radiotherapy (RT) in prostate cancer to apply high single doses in a few fractions. Using the Cyberknife® robotic system multiple non-coplanar fields are usually given with a treatment time of one hour or more. We planned to evaluate organ motion in this setting injecting a hydrogel spacer to protect the anterior rectal wall during treatment.Methods: A 66 years old man with low risk prostate cancer was planned for robotic hypofractionated stereotactic RT. After implantation of fiducial markers and a hydrogel spacer a total dose of 36.25 Gy in 5 fractions was given to the planning target volume (clinical target volume + 3 mm). After each beam the corresponding data reporting on the intra-fractional movement were pre-processed, the generated log-files extracted and the data analysed according to different directions: left -right (LR); anterior - posterior (AP); inferior -superior (IS). Clinical assessments were prospectively done before RT start, one week after the end of treatment as well as 1, 6 and 12 months afterwards. Symptoms were documented using Common Toxicity and Adverse Events Criteria 4.0.Results: Tolerability of marker and hydrogel implantation was excellent. A total of 284 non-coplanar fields were used per fraction. The total treatment time for all fields per fraction lasted more than 60 minutes. The detected and corrected movements over all 5 fractions were in a range of +/- 4 mm in all directions (LR: mean 0,238 - SD 0,798; AP: mean 0,450 - SD 1,690; and IS: mean 0,908 - SD 1,518). V36Gy for the rectum was 0.062 ccm. After RT, grade 1-2 intestinal toxicity and grade 1 genitourinarytoxicity occurred, but resolved completely after 10 days. On 1-, 6- and 12-months follow-up the patient was free of any symptoms with only slight decrease of erectile function (grade 1). There was a continuous PSA decline.Conclusions: Prostate movement was relatively low (+/- 4 mm) even during fraction times of more than 60 minutes. The hydrogel spacer might serve as a kind of stabilisator for the prostate, but this should be analysed in a larger cohort of patients.

Cite

CITATION STYLE

APA

Sumila, M., Mack, A., Schneider, U., Storelli, F., Curschmann, J., & Gruber, G. (2014). Long-term intra-fractional motion of the prostate using hydrogel spacer during Cyberknife® treatment for prostate cancer - a case report. Radiation Oncology, 9(1), 1–6. https://doi.org/10.1186/1748-717X-9-186

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free