Variable effects of changes in flow rate through the aortic, pulmonary and mitral valves on valve area and flow velocity: Impact on quantitative doppler flow calculations

163Citations
Citations of this article
21Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Doppler echocardiographic methods for measuring volumetric flow through the aortic, pulmonary and mitral salves provide the cardiologist with several potentially interchangeable noninvasive methods for determining cardiac output. In addition, comparison of flow differences through individual valves offers the potential to quantitate shunt flow and regurgitant volumes. To date, however, no study has compared the relative accuracies of each of these flow measurements in a controlled experimental setting. Therefore, in this study, Doppler echocardiography was used to measure aortic, pulmonary and mitral valve flows in seven open chest dogs on right atrial bypass where forward cardiac output was precisely controlled with a roller pump. Correlations with roller pump output were better for Doppler measurements of aortic (r = 0.98, SD = 0.3) and mitral (r = 0.97, SD = 0.3) than for pulmonary (r = 0.93, SD = 0.5) valve flow. Interobserver reproducibility was also better for aortic (r = 0.94) and mitral (r = 0.97) than for pulmonary (r = 0.88) valve flow measurements. All valves showed flow-related increases in cross-sectional area, but the slope of this response was variable: 0.05, 0.16 and 0.21 for the aortic, the pulmonary and the mitral valve, respectively. Increased forward flow through the aortic valve, therefore, was manifested primarily by an increase in velocity, whereas increasing flow through the pulmonary and mitral valves produced more significant area changes with correspondingly smaller increases in the velocity component. Recalculation of Doppler-deiermined outputs, assuming a fixed valve area for the entire range of flows, resulted in a decreased correlation with roller pump output. Both velocity and valve area should be measured at each flow rate for greatest accuracy in volumetric flow calculations. © 1985, American College of Cardiology Foundation. All rights reserved.

Cite

CITATION STYLE

APA

Stewart, W. J., Jiang, L., Mich, R., Pandian, N., Guerrero, J. L., & Weyman, A. E. (1985). Variable effects of changes in flow rate through the aortic, pulmonary and mitral valves on valve area and flow velocity: Impact on quantitative doppler flow calculations. Journal of the American College of Cardiology, 6(3), 653–662. https://doi.org/10.1016/S0735-1097(85)80127-3

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free