Abstract
—For satellite applications payload measurements are a crucial part of the radio frequency validation campaign before the launch. Parameters like Equivalent Isotropic Radiated Power (EIRP), Input Power Flux Density (IPFD), Gain over Noise Temperature (G/T), Gain over Frequency (G/F), Group Delay, and Passive Intermodulation (PIM) are to be measured in suitable facilities on satellite level. State-of-the-art payload measurements are conducted in compensated compact range facilities which offer a real-time test capability which is easy to setup and use. Closed link tests are straightforward to realize with two compact range feeds employing feed scanning. The measurement techniques as well as the error budgets are well known. Near-field facilities are widely used for antenna pattern measurements. However, there is not much literature available discussing in particular measurements of G/T, G/F, and Group Delay in the near field. Measurements of the above parameters in the near field seem to be feasible, however, the processing of the measured data has to be adapted and further calibration measurements are required. In this paper a comparison of payload measurement campaigns in near field and compact range facilities will be drawn. The techniques will be compared in terms of measurement timing and effort, practicability for satellite applications, and achievable accuracies.
Cite
CITATION STYLE
Schmidt, C. H., Migl, J., Geise, A., & Steiner, H.-J. (2015). Comparison of Payload Applications in Near Field and Compact Range Facilities. Antenna Measurement Techniques Association.
Register to see more suggestions