The European lightning location system EUCLID – Part 1: Performance validation

  • Schulz W
  • Diendorfer G
  • Pedeboy S
  • et al.
N/ACitations
Citations of this article
4Readers
Mendeley users who have this article in their library.

Abstract

Abstract. In this paper we present a performance analysis of the European lightning location system EUCLID in terms of location accuracy (LA), detection efficiency (DE) and peak current estimation. The performance analysis is based on ground truth data from direct lightning current measurements at the Gaisberg Tower (GBT) and data from E-field and video recordings. The E-field and video recordings were collected in three different regions in Europe, namely in Austria, Belgium, and France. The analysis shows a significant improvement of the LA of the EUCLID network over the past seven years. Currently, the median LA is in the range of 100 m. The observed DE in Austria and Belgium is similar, yet a slightly lower DE is determined in a particular region in France, due to malfunctioning of a relevant lightning location sensor during the time of observation. The overall accuracy of the lightning location system (LLS) peak current estimation for subsequent strokes is reasonable keeping in mind that the LLS estimated peak currents are determined from the radiated electromagnetic fields, assuming a constant return stroke speed. The results presented in this paper can be used to estimate the performance of the EUCLID network for regions with similar sensor baselines and sensor technology.

Cite

CITATION STYLE

APA

Schulz, W., Diendorfer, G., Pedeboy, S., & Poelman, D. R. (2015). The European lightning location system EUCLID – Part 1: Performance validation. Natural Hazards and Earth System Sciences Discussions, 3(9), 5325–5355.

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free