Purpose: The aim of this retrospective study was to analyze tumor control, toxicity, and aesthetic outcome of patients affected by non-melanoma skin cancer (NMSC) and treated with iridium-192 (192Ir) high-dose-rate (HDR) brachytherapy (BT) using Valencia applicators at the Division of Radiotherapy, University of Pisa. Material and methods: From June 2015 to December 2020, 95 NMSC patients, including 61.5% basal cell carcinoma and 38.5% squamous cell carcinoma patients, with median age of 83 years (range, 32-96 years) were treated. In total, 182 lesions with a diameter ≤ 25 mm (median, 12 mm) and a depth ≤ 4 mm, located in scalp (19.2%), face (20.9%), chest (8.8%), nose (16.5%), ear (15.4%), and extremities (19.2%) were analyzed. All lesions were treated with 192Ir-based HDR afterloader using Valencia applicators. 105 lesions (57.7%) were treated with applicator of 20 mm and 77 lesions (42.3%) with applicator of 30 mm in diameter, depending on the size of lesions. Prescribed dose was 40 Gy in 8 fractions (5 Gy/fraction) delivered 2-3 times a week. Biological effective dose (BED) was ≈ 60 Gy. Results: The median follow-up was 14 months (range, 3-59 months). The 2-year local control rate was 96%. According to common terminology criteria for adverse events (CTCAE v. 5.0), G1-G2 acute toxicities included dermatitis (22.0%) and pain (8.2%). The most common G1 late toxicities were hypopigmentation (27.5%) and fibrosis (8.2%), and G2 late toxicity included ulceration (0.5%). No G3 or higher acute or late toxicities were reported. Excellent cosmetic results were observed in 77.5% of the lesions, with one only (0.5%) reported as a poor cosmetic result (ulceration refractory to therapy). Conclusions: HDR-BT using Valencia applicators is a safe, effective, and well-tolerated treatment modality for NMSC, and can be considered a good alternative for treatment, especially in elderly patients who are often unfit for surgery.

Cite

CITATION STYLE

APA

Laliscia, C., Coccia, N., Fuentes, T., Perrone, F., & Paiar, F. (2021). Two different sizes of Valencia applicators in non-melanoma skin cancer treatment with iridium-192 high-dose-rate brachytherapy. Journal of Contemporary Brachytherapy, 13(6), 615–619. https://doi.org/10.5114/jcb.2021.112111

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free