Diagnostic efficacy of the magnetic resonance T1w/T2w ratio for the middle cerebellar peduncle in multiple system atrophy and spinocerebellar ataxia: A preliminary study

6Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background The standardized T1-weighted/T2-weighted (sT1w/T2w) ratio for the middle cerebellar peduncle (MCP) has been reported to be sensitive for detecting degenerative changes in the cerebellar subtype of multiple system atrophy (MSA-C), even in the early stages. We aimed to investigate the diagnostic value of the MCP sT1w/T2w ratio for differentiating between MSA-C and spinocerebellar ataxia (SCA). Methods We included 32 MSA-C, 8 SCA type 3 (SCA3), 16 SCA type 6 (SCA6) patients, and 17 controls, and the MCP sT1w/T2w ratio was analyzed using a region-of-interest approach. The diagnostic performance of the MCP sT1w/T2w ratio in discriminating among MSA-C, SCA3, and SCA6 was assessed and compared with diagnosis based on visual interpretation of MCP hyperintensities and the "hot cross bun"(HCB) sign. Results MCP sT1w/T2w ratio values were markedly lower in patients with MSA-C than in those with SCA3, those with SCA6, and controls (p < 0.001). The MCP sT1w/T2w ratio showed high diagnostic accuracy for distinguishing MSA-C from SCA3 (area under curve = 0.934), SCA6 (area under curve = 0.965), and controls (area under curve = 0.980). The diagnostic accuracy of the MCP sT1w/T2w ratio for differentiating MSA-C from SCA3 or SCA6 (90.0% for MSA-C vs. SCA3, and 91.7% for MSA-C vs. SCA6) was comparable to or superior than that of visual interpretation of MCP hyperintensities (80.0-87.5% in MSA-C vs. SCA3 and 87.6- 97.9% in MSA-C vs. SCA6) or the HCB sign (72.5-80.0% in MSA-C vs. SCA3 and 77.1- 93.8% in MSA-C vs. SCA6). Conclusions The MCP sT1w/T2w ratio might be a sensitive imaging-based marker for detecting MSA-Crelated changes and differentiating MSA-C from SCA3 or SCA6.

Cite

CITATION STYLE

APA

Wang, J., Sugiyama, A., Yokota, H., Hirano, S., Cooper, G., Mukai, H., … Kuwabara, S. (2022). Diagnostic efficacy of the magnetic resonance T1w/T2w ratio for the middle cerebellar peduncle in multiple system atrophy and spinocerebellar ataxia: A preliminary study. PLoS ONE, 17(4 April). https://doi.org/10.1371/journal.pone.0267024

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free