An alternative electroretinography protocol for children: a study of diagnostic agreement and accuracy relative to ISCEV standard electroretinograms

22Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To assess the diagnostic accuracy and agreement between a paediatric electroretinography protocol used at Great Ormond Street Hospital (GOSH-ERG) and the ‘gold standard’ international protocol (ISCEV-ERG) in health and disease. Methods: Patient databases between 2010 and 2020 were screened to identify children with an ISCEV-ERG recorded within four years of a GOSH-ERG. Electroretinogram (ERG) component peak times and amplitudes were re-measured, and data were analysed in terms of absolute abnormality and proportional deviation from respective reference ranges. Abnormality was defined by the retinal system affected and by individual ERG a- and b-wave component analysis. Results: A total of 59 patients were included: 38 patients had retinal disease defined by an abnormal ISCEV-ERG and 21 had normal ISCEV-ERGs. When absolute abnormality was defined by combined retinal systems, the GOSH-ERG showed an excellent overall sensitivity of 95% (accuracy 86%). Individual retinal systems showed good–excellent sensitivity (67%–100%) and specificity (68%–97%). Electroretinogram (ERG) component sensitivities ranged between 60% and 97% and specificities between 79% and 97% dependent upon the protocol step. The proportional relationship appeared mostly linear between protocols. Electroretinogram (ERG) morphology was comparable for both protocols in a range of retinal diseases including those with pathognomonic ERGs. Conclusion: We demonstrate the high diagnostic accuracy of a paediatric ERG protocol (GOSH-ERG) relative to ISCEV standard ERGs. The close proportional deviation and similar waveform morphology indicate ERGs from each protocol are similarly affected in disease. This encourages the use of the GOSH-ERG protocol in the screening, diagnosis and monitoring of retinal disease in children who are unable to comply with the rigorous ISCEV-ERG protocol.

Cite

CITATION STYLE

APA

Marmoy, O. R., Moinuddin, M., & Thompson, D. A. (2022). An alternative electroretinography protocol for children: a study of diagnostic agreement and accuracy relative to ISCEV standard electroretinograms. Acta Ophthalmologica, 100(3), 322–330. https://doi.org/10.1111/aos.14938

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free