Intentional depressurization of steam generator secondary side during a PWR small-break loss-of-coolant accident

22Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The consequence of intentional depressurization of the steam generator (SG) secondary side during a small break loss-of-coolant accident (LOCA) in a pressurized water reactor (PWR) was studied using the ROSA-IV Large Scale Test Facility (LSTF). The LSTF is a 1:48 volumetrically scaled full-height model of a Westinghouse-type PWR. The experiment simulated a 0.5% cold leg small-break LOCA with total failure of high pressure injection (HPI) system. The SG secondary-side atmospheric relief valve (ARV) was latched open after the core top region was uncovered. Then, the primary pressure closely followed the secondary pressure and dropped to the accumulator (ACC) injection pressure of 4.51 MPa before the core became severely overheated. A post test analysis, which was performed using the RELAP5/ MOD2 code with modifications made by the authors, predicted well the primary and secondary side responses during this experiment. © 1995 Taylor & Francis Group, LLC.

Cite

CITATION STYLE

APA

Asaka, H., & Kukita, Y. (1995). Intentional depressurization of steam generator secondary side during a PWR small-break loss-of-coolant accident. Journal of Nuclear Science and Technology, 32(2), 101–110. https://doi.org/10.1080/18811248.1995.9731679